May 26, 2017 Craig Nyssen News Comments Off

The  i600/i601 USB Data logger is a 16 single ended or 8 differential channel data acquisition system connecting voltage, thermocouple, thermistor, RTD, load cell, strain gage, potentiometer, current and resistant sensors to the PC via USB. The i600/i601 USB data logger is a rugged, compact, USB powered and highly accurate data acquisition system providing 8 or 16 different sensor types without additional signal conditioning is required. The i600/i601 USB data logger runs on a variety of different software such as MATLAB and LabVIEW.

FEATURESi600_and_i601_with_icons

  • The i600/i601 USB data logger connects a windows computer to sensors and controls via analogue inputs, digital inputs and digital outputs.
  • The i601 product provides ±36V bank electrical isolation; whereas the less costly i600 connects I/O signal ground to computer ground. i60x receives power from USB bus.
  • 16se/8di voltage input channels with extremely accurate 24-bit A/D converter
  • 4x digital I/O (4mA sink/source, 0 to 3.3V)
  • Connect directly to sensors: voltage,  thermocouple,  thermistor,  RTD,  load Cell,  strain gage,  potentiometer,  current,  resistance

PRODUCT SUMMARY

  • This A/D module provides 16se/8di voltage input channels (Ch#1…#16), each of which are independently software programmable with Windows software that support the direct connection to many common sensor types
  • Voltage input range on each channel is independently software programmable to one of: ±20mV, ±40mV, ±80mV, ±150mV, ±300mV, ±600mV, ±1.2V, ±2.5V, ±5V, ±10V
  • Included is a mating Hd44 Female Connector & Cover. Alternatively, one can attach i600/i601 to the following optional wiring boxes: i510,  i511,  i512. If one is working with thermocouples, an i510 wiring box is required due to its internal cold junction compensation.software_313x165
  • i600 and i601 are stand-alone USB data acquisition systems. No additional components, such as external power supply, are required. Included in the box: i60x Hardware Device, USB Cable, Software on CD, Mating Hd44 Female Connector & Hd44 Cover. For details, see the i60x Installation Guide.
  • Digitize at a maximum sample rate of 160K sample/sec for 1 channel, 12Ks/sec/ch for 2 channels, 6Ks/sec/ch for 4 channels, and 3Ks/sec/ch for 8 channels. For more details, see Voltage Accuracy.
  • Each channel provides the following software programmable parameters: A/D Signal-Averaging-Per-Point (0 … 100mSec), Sample-Rate (samples-per-second-per-channel), Digital IIR Filter (LowPass, HighPass, BandPass, or BandStop), Voltage Measurement Range (±20mV…±10V), Sensor Type, and Single-Ended or Differential Wiring
  • Excitation power (+3.3V ±0.2V, <80mA, 28mA per sensor max) is provided for sensors, along with other End User Power voltages. This 3.3V, which is referenced to instruNet Ground, is automatically readback by A/D when calculating sensor values.
  • The 4mA sink/source digital I/O port consists of 4 individual TTL-compatible lines (Ch#25…#28), each of which can be configured as: input or output bit When configured as an input, a channel can be used to sense a digital high (2 to 5.5 Volts) or digital low (0V to 0.8Volts). When configured as an output, a channel can be set high (e.g. >2V) or low (e.g. <0.8V). These I/O pins are short-circuit protected against high voltages up to 6.0V and down to -6.0

inet_circle4_i60x_670w

Analog Voltage Input (A/D), iNet-600 & iNet-601

Parameter

Specifications

Notes

Description 16se/8di Voltage Input Channels with extremely accurate 24-bit A/D Converter This A/D module provides 16se/8di voltage input channels (Ch#1…#16), each of which are independently software programmable with Windows software that support the direct connection to many common sensor types
Absolute Accuracy Specified Error components (i.e. INL, DNL, linearity, noise, temperature drift , time stability) are summed and specified as “Absolute Accuracy” with the following supported sensors (click for accuracy and maximum sample rate): Voltage,  Thermocouple,  Thermistor,  RTD,  Load Cell,  Strain Gage,  Potentiometer, Current,  Resistance
Voltage Ranges ±20mV … ±10V Voltage input range on each channel is independently software programmable to one of: ±20mV, ±40mV, ±80mV, ±150mV, ±300mV, ±600mV, ±1.2V, ±2.5V, ±5V, ±10V
Internal A/D 24-bit Internal 24-bit A/D Converter resolves voltage input range to ±8.4M digital value.
Sensors Direct Connect Each of the 8 differential channels support the direct connection to the following sensor types (click for Wiring Diagram and Setup Instructions): Voltage,  Thermocouple,  Thermistor,  RTD,  Load Cell,  Strain Gage,  Potentiometer,  Current,  Resistance
Channel Amplifiers Software Programmable Each channel provides the following software programmable parameters: A/D Signal-Averaging-Per-Point (0 … 100mSec), Sample-Rate (samples-per-second-per-channel), Digital IIR Filter (LowPass, HighPass, BandPass, or BandStop), Voltage Measurement Range (±20mV…±10V), Sensor Type, and Single-Ended or Differential Wiring
Wiring Single-Ended or Differential Single-ended (SE) wiring involves measuring the voltage between the input pin and instruNet Ground; whereas Differential (DI) wiring involves measuring the voltage between two input pins
Protected Voltage -30 to +30V Short any combination of voltage input channels to external -30 to +30V power source (i.e. capable of high current), instruNet power on or off, any duration, without damage
Bandwidth Depends on Voltage Range See absolute accuracy specification tables below (e.g. Voltage Accuracy) for bandwidth details
RFI Filter 13 KHz RFI filter
on ≤ ±150mVrange
RFI filter is a low pass filter that rejects high frequencies that could cause small measurement errors if left unfiltered
Digital Filter LowPass, HighPass, BandPass, or BandStop Each channel provides optional digital IIR lowpass, highpass, bandpass and bandstop filters with independent software programmable cut-off frequency, minimum dB stopband attenuation, maximum dB passband attenuation, and filter type (e.g. Elliptic, Chebyshev B, Chebyshev S, and Butterworth). Number of poles/zeros (i.e. “filter order”) is programmable between 2 and 32.
Maximum Sample Rate 160Ks/sec/aggregate Digitize at a maximum sample rate of 160K sample/sec for 1 channel on largest voltage input range. More channels at same voltage input range involves slower rates, e.g. 12Ks/sec per channel for 2 channels, 6Ks/sec/ch for 4 channels, and 3Ks/sec/ch for 8 channels. For a detail on maximum sample rate and bandwidth with different voltage input ranges, sensor types, and a/d averaging; see absolute accuracy specification tables below (e.g. Voltage Accuracy). Sample rate is set accurate to 50 ppm (e.g. user specifies 20000 s/sec yet system digitizes at 20001 s/sec). Minimum sample rate is 0.015 samples/sec/ch.
Sensor Excitation Included Excitation power (+3.3V ±0.2V, <80mA, 28mA per sensor max) is provided for sensors, along with other End User Power voltages. This 3.3V, which is referenced to instruNet Ground, is automatically readback by A/D when calculating sensor values.

4x Digital I/O, 4mA sink/source, iNet-600 & iNet-601

Parameter

Specifications

Notes

Description 4 Bidirectional Digital I/O The 4mA sink/source digital I/O port consists of 4 individual TTL-compatible lines (Ch#25…#28), each of which can be configured as: input or output bit. When configured as an input, a channel can be used to sense a digital high (2 to 5.5 Volts) or digital low (0V to 0.8Volts). When configured as an output, a channel can be set high (e.g. >2V) or low (e.g. <0.8V). These I/O pins are short-circuit protected against high voltages up to 6.0V and down to -6.0V.
Function input or output bit Each bit is independently software programmed as an input or output
TTL Compatible Yes Supports 0.8V for logic 0 and 2V for logic 1, which is typical for TTL
3.3V CMOS Compatible Supports 1.1V (3.3V*.35) for logic 0 and 2.3V (3.3V*.7) for logic 1, which is typical for digital Cmos powered by 3.3V
Drive Relay Directly Wire one side of external relay coil to power supply (e.g. 5V), wire other side to I/O pin, and output logic 0 to turn on relay
Detect Switch Closure Wire one side of external switch to and, wire other side to I/O pin, input logic 0 when switch is closed, and input logic 1 when switch is open

Physical/Environmental Specifications, iNet-600 & iNet-601

Parameter

Specifications

Notes

I/O Connector HD44 male High density 44 pin male connector (e.g. Astron #HD6C-44-AMAN-1G213 , click footnote for datasheet, outer shell is same size as DB25)
Wiring Box Compatible Compatible with the following optional wiring boxes: i510,  i511,  i512
Physical Dimensions 3.784″ x 0.924″ x 2.286″ For details, see i60x Mechanical Drawing
Operating Temp. 1 to 70°C Operate in temperature between 1°C and 70°C, no condensation
Storage Temperature -20 to 70°C Store in ambient temperature between -20°C and +70°C
Relative Humidity ≤ 90% Operate in humidity less than 90%, no condensation
Hot Plug & Play Yes One can attach device with power on or off, without damage
USB Interface 2.0 Transfer data to/from device at 480Mbits/sec
Safety IEC, EN, UL, CSA Designed to meet IEC 61010-1, EN 61010-1, UL 61010-1, CSA 61010-1
Emissions EN, CE, FCC Designed to meet EN 61326 EMC Min Immunity, EN 55011 Emissions Group 1 Class A, CE, C-tick, ICES, and FCC Part 15 Emissions Class A
CE Compliance Yes Meets 73/23/EEC low-voltage safety, and 89/336/EEC electromagnetic compatibility
Specifications Subject to change All specifications are subject to change without notice
+5V USB Power, Max +5V ±0.4V, ~433mA Power drawn from USB bus, with max load from end user sensors
+5V USB Power, Type +5V ±0.4V, ~255mA Power drawn from USB bus, with no load from end user sensors

Optional i51x Wiring Box

 i510_400w_294h_2xSize  i511_400w_292h_2xSize  i512_400w_275h
i510 Low Cost Wiring Box i511 BNC Wiring Box i512 Wiring Box

 Optional Accessories

 iwplus_screen  software_313x165-1  precision_resistors_NoClick_175w_189h
instruNet World PLUS Software (iW+) Application Software Shunt Resistors

For a further discussion contact our Melbourne office by email or phone: +61 3 9874 5777