KPSI 351 Series Pressure Transducer

KPSI 351 Series Pressure Transducer Description: The MEAS KPSI 351 submersible hydrostatic level transducer is specifically designed for small bore high accuracy applications and to meet the rigorous environments encountered in ground water level measurements. Incorporating a highly stable media-isolated sensor, the MEAS KPSI 351 features SDI-12 serial-digital interface. SDI-12 is […]

KPSI 351 Series Pressure Transducer

Description: The MEAS KPSI 351 submersible hydrostatic level transducer is specifically designed for small bore high accuracy applications and to meet the rigorous environments encountered in ground water level measurements. Incorporating a highly stable media-isolated sensor, the MEAS KPSI 351 features SDI-12 serial-digital interface. SDI-12 is a standard for interfacing data recorders with microprocessor-based sensors, especially in the environmental monitoring field. The MEAS KPSI 351 is intended for applications with requirements that include battery-powered operation with minimal current drain, low system cost, and use of a single recorder with multiple sensors “daisy-chained” on one cable. It will accommodate cable lengths between sensors and recorder up to 200 feet. Our new removable cable option allows easy substitution of transducers and cables.

Features:

±0.01 ft H2O, reading <= 10 ft (3m) H2O

±0.10% reading > 10 ft (3m) H2O

SDI-12 Digital Output

Removable Cable Option

0.75” Small Bore Diameter

Optional Lifetime Lightning Protection

Two Year Warranty

Welded 316 Stainless Steel or Titanium Body Material

Custom Lengths of Polyurethane or ETFE Cable up to 9,999 Feet

Shipped with Long-life Vent Filter

Custom Level Ranges up to 50 ft (15M) H2O

Parameter

Comment

LEVEL RANGES
Full Scale Level Ranges
(intermediate level ranges

10 thru 50 ft (3 thru 15 m) H20

Vented Gage Reference

are available)
Proof Pressure

1.5 x FS

Burst Pressure

2.0 x FS

STATIC PERFORMANCE (Combined Errors Due to Nonlinearity, Hysteresis, Nonrepeatability, and Thermal Effects over the Compensated Temperature Range)

Level

±0.01 ft H20

for reading <= 10 ft (3m) H2O

±0.10% reading

for reading > 10 ft (3m) H2O

Temperature

0.5ºC

Excitation

±0.5 VDC

8 to 28 volts

Resolution

0.0001% FS

MEASUREMENT RESOLUTION
Level

±0.0001%FS

Temperature

±0.001ºC

Excitation

±0.1 VDC

ENVIRONMENTAL
Wetted Materials

316 SS or Titanium; POM;

polyurethane  or FKM

Compensated Temp Range

0 to 50ºC

Operating Temp Range

-20 to 60 ºC

when attached to polyurethane cable

Protection Rating

IP 68, NEMA 6P

ELECTRICAL
Excitation

6-28V – VDC output

Input Current

8 mA max

average current during data acquisition

1.0 mA

quiescent

Interface

SDI-12, version 1.3

SDI-12 protocol

RS-485

CERTIFICATIONS

CE compliant

EN 61326-1:2001 and 61326-2-3:2006

PHYSICAL
Approximate Weight

0.75  lbs (340 g) transducer

0.05 lbs/ft (79 g/m) cable

Cable Jacket Material

Polyurethane (standard)

ETFE (optional)

Cable Pull Strength

200 lbs (90 kg)

Cable Number of Conductors

4

Cable Conductor Size

22 AWG

Cable Seal

Molded Polyurethane

for polyurethane cable

FKM Gland

for ETFE cable

No Information Available.