ATEQ C540 + F20 Series Leak Testers

ATEQ C540 F20 Series Leak Testers A new concept for faster and more cost-effective leak tests. One central unit (ATEQ C540) controls up to 10 ATEQ F20’s, which can be mounted close to the test parts, ensuring the best possible measurement conditions.  Main Features: Differential decay leak measurement 3 ranges […]

ATEQ C540 F20 Series Leak Testers

A new concept for faster and more cost-effective leak tests. One central unit (ATEQ C540) controls up to 10 ATEQ F20’s, which can be mounted close to the test parts, ensuring the best possible measurement conditions. 

Main Features:

  • Differential decay leak measurement
  • 3 ranges of leak measurement (∆P) Full scale: 50 Pa or 500 Pa or 5000 Pa
  • Outputs and regulation via front or rear front panel
  • 64 programs / head
  • Versatile mounting: panel, on module, free-standing
  • Multi-test and multi-head control
  • Compact (1/2 19″)

C540 F20

Technology Differential pressure decay
Measurement range 3 ranges of leak
measurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa
Test modes Test modes :
DP
DP/Dt
Flow units
Blockage test
Additional ones depending
on your applications
Programs 64 programs / head
Calibration Manual calibration on front
panel using calibrated leak
Networking RS232: PC and
configuration / storage
module
RS485: ATEQ network
Dimensions W/H/D (mm) (C540) : 287 x 250 x 180
(F20) : 136 x 250 x 180
Weight (Kg) (C540): 4.5
(F20) : 4
Interface 14 digits and graphical
display (C540)
4-line LCD screen (F20 option)
Results indicator lights (F20 option)
Power supply 24 V DC 1 .6 A
Main adapter included
(110 – 240 V AC)
Air requirements Clean and dry air required
Air quality standard to be
applied (ISO 8573-1)
Temperature Operating : 0°C to 45°C
Storage : 0°C to 60°C
Options C540 :
14 inputs / 14 outputs
F20 : 7 inputs / 5 outputs
LCD display
Electronic regulator
Dual pressure
High speed valve
2 pneumatic outputs for
control of sealing connectors
6 x 24 V programmable
outputs for external connection
2 analog outputs:
0 – 10 V or 4 – 20mA
Automatic calibration check
Temperature compensation
Modbus (Field bus)

 

Dimensions W/H/D (mm) (C540) : 287 x 250 x 180
(F20) : 136 x 250 x 180
Temperature Operating : 0°C to 45°C
Storage : 0°C to 60°C