ATEQ Omicron ADSE 745 Pitot Static Tester

ATEQ Omicron ADSE 745 Pitot Static Tester The ADSE 745 caters fully for all aircraft types and the different electrical power supplies. It can be used for testing high performance civil and military aircraft, fix and rotary wing. The multi-pressure outlets option can suit the more complex pilot-static-systems. This Pitot Static tester is […]

ATEQ Omicron ADSE 745 Pitot Static Tester

The ADSE 745 caters fully for all aircraft types and the different electrical power supplies. It can be used for testing high performance civil and military aircraft, fix and rotary wing. The multi-pressure outlets option can suit the more complex pilot-static-systems. This Pitot Static tester is designed primarily for flightline use to cover the testing of all barometric and manometric pressure instrument systems.

The large touch screen display,with on-screenhelp, enables all checks to be carried out easily on the flight deck or in the cockpit, by a single operator. The test set is robust and housed in a mobile weatherproof case fitted with rugged tyre wheels. An attached bag contains the pressure hoses and electrical cables.

Accessories to suit specific applications may be supplied.

Main Features

  • Built-in pressure and vacuum pumps
  • Liquid crystal colour display with touch sensitive screen for operator instructions/help
  • Remote control unit based on Windows CE tablet PC
  • Complete self check of set before use
  • High accuracy, high resolution
  • RVSM compliant
  • Programmable leak test
  • Programmable flight envelope to protect equipment under test
  • All four primary flight parameters display ed simultaneously
  • Programmable (password write protected) test schedules – 24 programmes available
  • Selectable pressure units: hPa; mb; in Hg; mmHg; ft; m; kts; km/h, ft/min; hm/min, Mach number

 

General details

Temperature range Operating -10° to 50°C (14° to 122°F)
Storage -20° to 60°C (–4° to 140°F)
Power supply 90/240V, 50 to 400Hz AC, 150VA
Case Completely weatherproof, meets EMC requirementsMIL STD 462D

Physical

320x270x715mm (12.5 x 10.6 x 28.1 inch) (case)440x420x715mm (17.3 x 16.5 x 28.1 inch) (overall) – 32kg (71 lbs)
Calibration Recommended period 12 months
Ease of Use Remote touch screen
Wheeled case for manoeuvrability
Integrated bag for cables and hoses
Ease of maintenance Maintenance limited to calibration, regular external cleaning and exchange of filters (with the calibration)

Optional

Multi-pressure outlet (2 Ps & 2 Pt) variant
DC Power supply: 17 to 32V DC
Rechargeable 24V battery pack (2h)
Bigger Pumps: 80,000ft – 15,000ft/min (up to 100,000ft – 60,000ft/min (Volume dependant)
Low range Pt sensor: 350 kts max for better accuracy
Remote Control Software for PC (Windows CE)
AoA option

Measurement specification

Function Range Accuracy
Altitude -2,300 to 60,000ft 1.5ft at 0ft
(up to -4,000ft to 100,000ft optional) 4ft at 30,000ft
16ft at 60,000ft
Altitude rate 0 to 6,000ft/min 1%
(up to 60,000m/min optional) 1%
Indicated 10 to 800 kts 1kt at 50kts ( 0.5kts at 50kts optional)
airspeed (up to 1000 kts optional) 0.2kt at 350kts ( 0.1kts at 350kts opt.)
0.04kt at 650kts
Mach N° 0.1 to 4.0 Mach 0.001M at 0,8M/25,000ft
(0.1 to 10 Mach optional) 0.002M at 1,7M/30,000ft
Static sensor 30 to 1200 mbar 0,01% FS
Pitot sensor 30 to 3000 mbar 0,01% FS

 

Physical

320x270x715mm (12.5 x 10.6 x 28.1 inch) (case)440x420x715mm (17.3 x 16.5 x 28.1 inch) (overall) – 32kg (71 lbs)
Temperature range Operating -10° to 50°C (14° to 122°F)
Storage -20° to 60°C (–4° to 140°F)