Differential Pressure Transducer D5100

Differential Pressure Transducer D5100 Description: The D5100 series from Measurement Specialties sets the price and performance standard for differential pressure transducers used in demanding environments. The amplified model of the D5100 series exceeds the latest heavy industrial CE requirements including surge protection and reverse polarity protection. The transducers have two pressure […]

Differential Pressure Transducer D5100

Description: The D5100 series from Measurement Specialties sets the price and performance standard for differential pressure transducers used in demanding environments. The amplified model of the D5100 series exceeds the latest heavy industrial CE requirements including surge protection and reverse polarity protection. The transducers have two pressure ports for high and low pressures and all wetted parts are made of 316L stainless steel. It comes in a variety of electrical configurations and ranges from 1 to 500 psi (up to 35 Bar).

Features:

  • Heavy Industrial CE Approval (amplified only)
  • As Low As ±0.1% Pressure Non Linearity
  • Rugged Construction: Can Withstand 50g Shock/20g Vibration
  • Up to -40°C to 125°C Operating Temperature Range
  • Excellent Stability
  • Various Output, Fitting, and Electrical Configuration Options
PARAMETERS   1 PSI     5 PSI       
  MIN TYP MAX MIN TYP MAX UNITS NOTES 
Accuracy -0.3   0.3   5psi: -0.25
≥15psi: -0.1
0.25
0.1 
%Span 1  1
Isolation, Body To Any Lead 1     1     mΩ @25VDC  
Pressure Cycles 1.00E 6     1.00E 6     0-FS Cycles  
Proof Pressure (High Side)     10X     3X Rated 2
Proof Pressure (Low Side)     10X      3X Rated 3
Burst Pressure (High Side)     12X     4X Rated 2
Burst Pressure (Low Side)     12X     4X Rated 3
Line (common) Pressure     1000     1000 psi  
Line Pressure Effect on Zero   0.004      5psi: 0.0008 TYP≥15psi: 0.0005 TYP    %Span/psi   
Long Term Stability   ±0.25      ±0.1   %Span/year  
Total Error Band -1.5   1.5 -1   1 %Span  
Compensated Temperature 0   50 0-20   70 85 °C   
Operating Temperature -40   85 -40   125 °C 4
Storage Temperature -40   125 -40 125   °C 4
Load Resistance (RL) RL > 100k Ω 5
Sensor Type Differential Pressure Sensor with Unidirectional Calibration
Pressure Port Material 316L Stainless Steel
Bandwidth DC to 1KHz (typical)
Shock 50g, 11 msec Half sine shock per MIL-STD-202F, Method 213B, Condition A
Vibration ±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L

No Information Available.