F1ANC11A – Load Cell – Pubic

Load Cell, 1-axial
Location: Pubic

Technical description

The applied force causes compression or strain of the base body. The deformation is measured using strain gauges. The wiring of multiple strain gauges for a full bridge circuit compensates for the temperature influence on the zero signal and the cross-influence from other force and torque application.

Force direction

Fy

Application

WSID 50%

Equivalent types

FTSS: W50-71051

Measurement specification

Resistive
Strain gauges

Options

ID-Module integrated in sensor
Polarity according to SAE J211

Technical specification

Unit Value
Fy
Measuring range kN 12
Sensitivity 1) µV/V/kN 200
Output signal 1), 2) mV/V 2.4
Bridge resistance Ω 700
Zero signal 1) mV/V ≤ 0.05
Amplitude non-linearity 3) % ≤ 1.0
Hysteresis 3) % ≤ 1.0
Channel cross talk 3) %
Supply voltage V 2–15
Ultimate load % 150
Insulation resistance > 100
Temperature range °C -30…+70
Weight (approximate) g 120

All values measured at 10 V sensor supply voltage and at 23 °C.
1) Typical value
2) At nominal load
3) Relative nominal range

F1ANC11A Dimensions

Temperature range °C -30…+70