Call Us Now! (03) 9874 5777Contact Us
Load Cell, 3-axial Location: Acetabulum right
Technical description
The applied force causes compression or strain of the base body. The deformation is measured using strain gauges. The wiring of multiple strain gauges for a full bridge circuit compensates for the temperature influence on the zero signal and the cross-influence from other force and torque application.
Force direction
Fx, Fy, Fz
Application
Thor
Equivalent types
Denton: 3455 Humanetics: 10670JI4
Measurement specification
Resistive Strain gauges
Options
ID-Module integrated in sensor Polarity according to SAE J211
Value
FX
FY
FZ
22.2
13.3
140
60
143
3.1
0.8
1.9
350
700
All values measured at 10 V sensor supply voltage and at 23 °C. 1) Typical value 2) At nominal load 3) Relative nominal range