F3AQF11A – Load Cell – Shoulder

Load Cell, 3-axial
Location: Shoulder

Technical description

The applied force causes compression or strain of the base body. The deformation is measured using strain gauges. The wiring of multiple strain gauges for a full bridge circuit compensates for the temperature influence on the zero signal and the cross-influence from other force and torque application.

Force direction

Fx, Fy, Fz

Application

EUROSID
ES2 RE
ES1/ ES2

Equivalent types

Denton: 3155
FTSS: IF-317

Measurement specification

Resistive
Strain gauges

Options

ID-Module integrated in sensor
Polarity according to SAE J211

Technical specification

Unit

Value

FX

FY

FZ

Measuring range kN

4.0

8.0

4.0

Sensitivity 1) µV/V/kN

575

238

575

Output signal 1), 2) mV/V

2.3

1.9

2.3

Bridge resistance Ω

350

700

350

Zero signal 1) mV/V ≤ 0.05
Amplitude non-linearity 3) % ≤ 1.0
Hysteresis 3) % ≤ 1.0
Channel cross talk 3) % ≤ 5.0
Supply voltage V 2–15
Ultimate load % 150
Insulation resistance > 100
Temperature range °C -30…+70
Weight (approximate) g 260

All values measured at 10 V sensor supply voltage and at 23 °C.
1) Typical value
2) At nominal load
3) Relative nominal range

F3AQF11A Dimensions

Temperature range °C -30…+70