Jewell ASXC Series Angular Accelerometer

The ASXC Angular Accelerometers are available in several standard Input Ranges from 1 to 100 rad/sec2

Jewell ASXC Series Angular Accelerometer

The ASXC Angular Accelerometers are available in several standard Input Ranges from 1 to 100 rad/sec2. They operate with an Input Voltage of 15 VDC and Input Current of 25 mA, and have an Operating Temperature range of approximately –30 to 70 degrees Celsius.

The ASXC Angular Accelerometers are designed to be small and lightweight, are extremely repeatable, and offer a very high output with excellent accuracy and stability.

STATIC/DYNAMIC

Input Range, rads/sec²

± 2

± 10

± 20

± 50

± 100

Full Range Output (FRO V ±1%)

± 5.0

± 5.0

± 5.0

± 5.0

± 5.0

Non Linearity (%FRO, Max.)

1.0

1.0

1.0

1.0

1.0

Scale Factor (V/rad/sec²)

5.000

1.000

0.500

0.200

0.100

Scale Factor Temp Sens (% reading/°C, Max.)

0.09

0.09

0.09

0.09

0.09

Bias (rad/sec²) ±0.005 ±0.020 ±0.030 ±0.080 ±0.100
Bias Temp. Sens. (FRO/°C, Max.) ±0.001 ±0.001 ±0.001 ±0.001 ±0.001
Bandwidth (-3dB) (Hz, Max.)

100

150

200

170

170

Damping Ratio (Nominal)

0.9

0.9

0.9

0.9

0.9

Transverse Axis Misalignment (°, Max.) ±0.025 ±0.025 ±0.025 ±0.025 ±0.025
Resolution and Threshold (rad/sec², g, Max.) ±0.001 ±0.001 ±0.002 ±0.005

±0.010

 

ELECTRICAL

# of Axis

1

Input Voltage (Vdc)

±10 to ±15

Input Current (mA, Nom.)

±25

Output Impedance (Ohms, Nom.)

100

Noise (Vrms, Max.)

0.030

0.030

0.050

0.050

0.050

ENVIRONMENTAL

 

Operating Temp Range

-30°C to 70°C

Survival Temp Range

-40°C to 70°C

Shock

100g, 11 msec, 1/2 sine

Seal

MIL-STD 202, Method 112

Weight

8.5 oz.

No Information Available.