Jewell DXI-100/200 Series Inclinometer

The Jewell DXI-100/200 Series single or dual digital inclinometer takes Jewell’s highly accurate analog closed loop sensor technology to the next level. Features & Benefits Digital output Resolution 0.001° Mechanical Shock 1500g 1msec 1/2 sine Industry Standard EIA RS485 and EIA RS422 output For use in high shock and vibration environments […]

The Jewell DXI-100/200 Series single or dual digital inclinometer takes Jewell’s highly accurate analog closed loop sensor technology to the next level.

Features & Benefits

  • Digital output
  • Resolution 0.001°
  • Mechanical Shock 1500g 1msec 1/2 sine
  • Industry Standard EIA RS485 and EIA RS422 output
  • For use in high shock and vibration environments
  • High Precision and Performance
  • Low Noise

Applications

  • Radar/Antenna Control
  • Structural Monitoring
  • Linear Acceleration/Deceleration Measuring
  • Automatic Train Position Control
  • Seismic Monitoring
  • Platform Leveling

Performance

Input Range¹, °

±1.0

±3.0

±14.5

±30.0

±60.0

Number of Axis

1,2

1,2

1,2

1,2

1,2

Non Linearity², %FRO, Max

0.02

0.015

0.02

0.02

0.03

Scale Factor Tolerance, % Max

0.05

0.05

0.05

0.05

0.05

Scale Factor Temperature Sensitivity, % reading/°C, Max

0.01

0.01

0.01

0.01

0.01

Output at 0° Tilt, °Max

0.01

0.01

0.05

0.05

0.05

Bias Temperature Sensitivity, millideg. /°C maximum

5

5

5

5

5

Bandwidth (-3dB), Hz, Nom³

3

6

30

30

30

Transverse Axis Misalignment, °, Max

0.05

0.05

0.5

0.5

0.5

Angular Resolution and Threshold, °

0.001

0.001

0.001

0.001

0.001

 

Digital Output

Interface

EIA-RS485/EIA-RS422

Protocol

Proprietary

Output Representation

Degrees

Baud Rate⁴

19200

38400

57600

115200

230400

 

Electrical

Supply Voltage, Volts DC

10 to 30

Input Current, mA, Max

DXI-100, 80 mA & DXI-200, 100 mA

 

Environmental

Operational Temp Range, °C

-40 to 70

Storage and Temp Range, °C

-40 to 70

Protection Class per IEC 529

IP67

NEMA Enclosure Rating

6

Seal

MILD-STD-202 Method 112

Shock Survival

1500g, 1msec, ½ sine

Vibration Survival, grms (20Hz to 2 KHz)

20

 

Enclosure

Housing Material

Anodized Aluminum

Weight

DXI-100 8oz [226.80 g]/ DXI-200 10oz [283.50 g]

Connector Type

MS27476Y10D35P

Recommended Mating Connector

MS27473T10B35S

 

No Information Available.