KPSI 342 Series Pressure Transducer Description: The MEAS KPSI 342 is a ± 0.25% FS TEB accuracy, 0.75″ diameter submersible hydrostatic level transducer that combines sensor competencies with the latest in Application Specific Integrated Circuit (ASIC) technology. Implementation of the ASIC provides unmatched sensor compensation over the entire operating range of […]
Description: The MEAS KPSI 342 is a ± 0.25% FS TEB accuracy, 0.75″ diameter submersible hydrostatic level transducer that combines sensor competencies with the latest in Application Specific Integrated Circuit (ASIC) technology. Implementation of the ASIC provides unmatched sensor compensation over the entire operating range of the pressure sensor. The Total Error Band specification (± 0.25% FS) over the complete operating temperature range (-20 to 85ºC) eliminates the user having to combine multiple performance specifications to understand the total accuracy of the transducer. All MEAS KPSI Transducers utilize a highly accurate pressure sensor assembly specifically designed for hostile fluids and gases. The assembly is integrated with supporting electronics in a durable waterproof housing constructed of 316 stainless steel or titanium. The attached electrical cable is custom manufactured and includes Kevlar® members to prevent errors due to cable elongation, and a unique water block feature that self-seals in the event of accidental cuts to the cable. Each transducer is shipped with a SuperDry™ Vent Filter that prevents moisture from entering the vent tube for at least one year without maintenance, even in the most humid environments.
Features:
Parameter Comment
LEVEL RANGES
Full Scale Level Ranges 10 thru 692 ft H2O (intermediate level (3 thru 211 m H2O) Vented Gage Reference ranges are available) 35 thru 692 ft H2O . (10 thru 211 m H2O) Sealed or Absolute Gage Reference
1.5 x FS
2.0 x FS
±0.25% TEB
Prorated for level ranges < = 23’ (7m) H2O
when operating > 60°C
0.0001% FS
316 SS or Titanium; POM;
polyurethane or FKM
-20 to 85º C
when attached to polyurethane cable
IP 68, NEMA 6P
9-30 VDC
mA output
20 mA max
4-20mA
±0.12 mA
See loop diagram for mA output
100 mega ohm at 50 VDC
Polarity, surge/shorted output
CE compliant
EN 61326-1:2001 and 61326-2-3:2006
0.50 lbs (224 g) transducer
0.05 lbs/ft (79 g/m) cable
Polyurethane (standard)
ETFE (optional)
200 lbs (90 kg)
4
22 AWG
Molded Polyurethane
for polyurethane cable
FKM Gland
for ETFE cable
LIGHTNING PROTECTION (power supply needs to be limited to 150mA to avoid lock up of the gas tube after a suppression event)
>1,000 Operations
36 Volts
<10 nsecs
20,000 Amperes