Miniature Strain Gauge Signal Conditioner, Converts Load Cell to 4-20mA & 0-10V (ICA S & H)

Miniature Strain Gauge Signal Conditioner, Converts Load Cell to 4-20mA & 0-10V (ICA S & H) The ICA range of Miniature Strain Gauge Signal Conditioners offer a high performance strain gauge amplifier in miniature OEM format, designed specifically for fitting inside load cells, converts load cell to 4-20mA & 0-10 […]

Miniature Strain Gauge Signal Conditioner, Converts Load Cell to 4-20mA & 0-10V (ICA S & H)

The ICA range of Miniature Strain Gauge Signal Conditioners offer a high performance strain gauge amplifier in miniature OEM format, designed specifically for fitting inside load cells, converts load cell to 4-20mA & 0-10 V output.

The ICA family offers high stability and fast response.

The Miniature Strain Gauge Signal Conditioner is available in 6 versions with two performance categories S & H (industrial & very high stability).

The ICAH range offer very low drift over wide operating temperatures.

ATEX certification pending on some variants.
Optional (ILE) in line enclosure to convert a standard load cell to a conditioned load cell output

  • Strain gauge conditioner and load cell amplifier
  • Miniature PCB format for fitting inside sensors, 19mm diameter, 7.6mm height
  • Standard excitation of 5V
  • Outputs of 4-20mA, 0-10V, 0-5V, ±10V
  • Non interaction between the trimmers makes calibration fast and easy
  • High speed 1000 Hz
  • User selectable span resistor
  • 2 wire 4-20mA load cell option
  • Robust design, of high noise immunity & reverse polarity protected
  • Option of an in-line enclosure (shown on thumbnail image on left)
ICA1,2,3,6 Voltage Output Amplifiers
ICA1 0.1-10.1V
Parameter Min Typical Max Units/Notes
Electrical & Environmental
Supply Voltage Range 13 24 30 Volts
Operating Current 23 mA Note 1
Operating Temp Range -40 85 ºC
Storage Temp Range -40 85 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 4.9 5 5.1 Volts
Bridge Impedance 330 350 5000 Ohms
Bridge Sensitivity 0.5 2.5 150 mV/V Note 2
Output Voltage Range 0.1 10.1 Volts
Output Load 5000 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.0009 0.0025 ±%FR/ºC
Zero Temp Stability H 0.0004 0.0015 ±%FR/ºC
Span Temp Stability S 0.0025 0.0064 ±%FR/ºC
Span Temp Stability H 0.002 0.0051 ±%FR/ºC
ICA2 0.1-5.1V
Electrical & Environmental
Supply Voltage Range 8.5  12 28 Volts
Operating Current 23 mA Note 1
Operating Temp Range -40 85 ºC
Storage Temp Range -40 85 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 4.9 5 5.1 Volts
Bridge Impedance 330 350 5000 Ohms
Bridge Sensitivity 0.5 2.5 150 mV/V Note 2
Output Voltage Range 0.1 ±5.1 Volts
Output Load 5000 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.0009 0.0025 ±%FR/ºC
Zero Temp Stability H 0.0004 0.0015 ±%FR/ºC
Span Temp Stability S 0.0025 0.0064 ±%FR/ºC
Span Temp Stability H 0.002 0.0051 ±%FR/ºC
ICA3 ±10V
Electrical & Environmental
Supply Voltage Range ±13 ±15 ±15 Volts
Operating Current 23 mA Note 1
Operating Temp Range -40 85 ºC
Storage Temp Range -40 85 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 4.9 5 5.1 Volts
Bridge Impedance 330 350 5000 Ohms
Bridge Sensitivity 0.5 2.5 150 mV/V Note 2
Output Voltage Range -10 10 Volts
Output Load 5000 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.0009 0.0025 ±%FR/ºC
Zero Temp Stability H 0.0004 0.0015 ±%FR/ºC
Span Temp Stability S 0.0025 0.0064 ±%FR/ºC
Span Temp Stability H 0.002 0.0051 ±%FR/ºC
ICA6 ±10V
Electrical & Environmental
Supply Voltage Range 14 15 18 Volts Note 3
Operating Current 30 mA Note 1
Operating Temp Range -40 85 ºC
Storage Temp Range -30 ºC
Reverse Polarity Protection Volts
Measurements
Bridge Excitation 4.9 5 5.1 Volts
Bridge Impedance 330 350 5000 Ohms
Bridge Sensitivity 0.5 2.5 150 mV/V Note 2
Output Voltage Range -10 10 Volts
Output Load 5000 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.0009 0.0025 ±%FR/ºC
Zero Temp Stability H 0.0004 0.0015 ±%FR/ºC
Span Temp Stability S 0.0025 0.0064 ±%FR/ºC
Span Temp Stability H 0.002 0.0051 ±%FR/ºC
ICA4,5 Current Output Amplifiers
ICA4 4-20mA
Electrical & Environmental
Supply Voltage Range 10 24 30 Volts Note 4
Operating Current 27 43 mA Note 1
Operating Temp Range -40 85 ºC
Storage Temp Range -40 85 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 4.9 5 5.1 Volts
Bridge Impedance 330 350 5000 Ohms
Bridge Sensitivity 0.5 2.5 150 mV/V  Note 2
Output Current Range 4 20 mA
Output Load 500 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.0009 0.0025 ±%FR/ºC
Zero Temp Stability H 0.0004 0.0015 ±%FR/ºC
Span Temp Stability S 0.0025 0.0064 ±%FR/ºC
Span Temp Stability H 0.002 0.0051 ±%FR/ºC
ICA5S 4-20mA
Electrical & Environmental
Supply voltage Range 7.5 24 30 Volts
Operating Current 4 20 mA (2 wire)
Operating Temp Range -40 85 ºC
Storage Temp Range -40 125 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 1.05 1.11 1.16 Volts Note 5
Bridge Impedance 350 1000 5000 Ohms Note 6
Bridge Sensitivity 0.5 2.5 55 mV/V Note 2
Output Current Range 4 20 mA
Output Load 800 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR Note 5
Span Adjustment ±8 %FR
Linearity  0.002 %FR
Zero Temp Stability S 0.001 0.005 ±%FR/ºC
Span Temp Stability S 0.007 0.014 ±%FR/ºC
ICA5A 4-20mA
Electrical & Environmental
Supply Voltage Range 9 24 30 Volts
Operating Current 4 20 mA (2 wire)
Operating Temp Range -40 85 ºC
Storage Temp Range -40 125 ºC
Reverse Polarity Protection -30 Volts
Measurements
Bridge Excitation 1.05 1.11 1.16 Volts Note 5
Bridge Impedance 350 1000 5000 Ohms Note 6
Bridge Sensitivity 0.5 2.5 55 mV/V Note 2
Output Current Range 4 20 mA
Output Load 800 Ohms
Band Width DC 1000 Hz
Zero Adjustment ±2 %FR Note 5
Span Adjustment ±8 %FR
Linearity 0.02 %FR
Zero Temp Stability S 0.001 0.005 ±%FR/ºC
Span Temp Stability S 0.007 0.014 ±%FR/ºC
Notes Note 1 – With 350 Ohm load cell connected.
Note 2 – Factory setting is the typical value shown. For other values fit an alternative calibration resistor (see manuals in Downloads tab).
Note 3 – ICA6 maximum voltage can be increased to 24V with a 1000 Ohm load cell.
Note 4 – The ICA4 can tolerate a lower supply voltage if the output load is reduced e.g. operation is possible at 8V provided that the load does not exceed 150 Ohm.
Note 5 – ICA5 with 1000 Ohms load cell connected.
Note 6 – ICA5 recommended bridge impedance is 1000 Ohms or greater.
General Notes The voltage between either of the power supply connections and the load cell shield should not exceed 50V. Any leakage will be greater than 10M Ohms.
FR = Full Range
Environmental    
Storage Temperature -40 to 85ºC
Operating Temperature -40 to 85ºC
Relative Humidity 95% maximum non condensing
CE Environmental Approvals European EMC Directive 2004/108/EC, Low Voltage Directive 2006/95/EC

 