N6ALB11A – Load Cell – Upper Neck

Load Cell, 6-axial
Location: Neck, Upper

Technical description

The applied force causes compression or strain of the base body. The deformation is measured using strain gauges. The wiring of multiple strain gauges for a full bridge circuit compensates for the temperature influence on the zero signal and the cross-influence from other force and torque application.

Force direction

Fx, Fy, Fz, Mx, My, Mz

Application

H3-5%, H3-50%, H3-95%,
SIDIIs, H3-6YO, H3-10YO

Equivalent types

Denton: 1716
FTSS: IF-205

Measurement specification

Resistive
Strain gauges

Options

ID-Module integrated in sensor
Polarity according to SAE J211

Technical specification

Unit Value
FX FY FZ MX MY MZ
Measuring range kN

Nm

8.9

 

8.9

 

13.5

 

 

283

 

283

 

283

Sensitivity 1) µV/V/kN

µV/V/Nm

180

 

170

 

90

 

 

5.3

 

5.3

 

7.8

Output signal 1), 2) mV/V 1.6 1.5 1.2 1.5 1.5 2.2
Bridge resistance Ω 350 350 700 350 350 700
Zero signal 1) mV/V ≤ 0.05
Amplitude non-linearity 3) % ≤ 1.0
Hysteresis 3) % ≤ 1.0
Channel cross talk 3) % ≤ 5.0
Supply voltage V 2–15
Ultimate load % 150
Insulation resistance > 100
Temperature range °C -30…+70
Weight (approximate) g 630

All values measured at 10 V sensor supply voltage and at 23 °C.
1) Typical value
2) At nominal load
3) Relative nominal range

N6ALB11A Dimensions

Temperature range °C -30…+70