P117 Slim-line Linear Position Sensor

P117 Slim-line Linear Position Sensor The P117 LIPS® (Linear Inductive Position Sensor)is an affordable, durable, high-accuracy position sensor designed for industrial and scientific feedback applications. The Repeatability, overall performance and stability are excellent over a large temperature range.The sensor is very space efficent and compact with its 19mm body diameter. […]

P117 Slim-line Linear Position Sensor

The P117 LIPS® (Linear Inductive Position Sensor)is an affordable, durable, high-accuracy position sensor designed for industrial and scientific feedback applications. The Repeatability, overall performance and stability are excellent over a large temperature range.The sensor is very space efficent and compact with its 19mm body diameter. The P117 is housed within a stainless steel body tube and has a 3/8″ stainless steel push rod.

Various mounting options are available including M5 male stud and M5 rod eye bearing. The push rod can be supplied free or captive with M5 male thread or M5 rod eye. Like all Positek products the P117 provides a linear output proportional to the displacement. Each unit is supplied calibrated to the customers exact requirement. For example, if your application requires 3/4″ (19 mm) measurement then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 19 mm.
The P117 is sealed to IP67 . The sensor has fully integrated EMC protection.

The Full Positek Range Also Offer a range of Intrinsically Safe and ANZEx approved to Ex ia I/IIC T4

Intrinsically Safe systems provide a safe operating environment for personnel and equipment. Intrinsic Safety (IS) is based on the principle of restricting the  electrical energy transmitted into a hazardous area, thereby ensuring that any sparks or heated surfaces that may occur as a result of electrical failures are insufficient to cause ignition. The threat of an explosion is eliminated.

Positek’s ATEX and IECEx approved Intrinsically Safe sensors can be used in hazardous environments when connected to our approved galvanically isolated amplifier. Positek offers Intrinsically Safe sensors for the following three hazard classifications:

  • ‘A’ Series ANZEx Approved Intrinsically Safe Sensors for Gas/Vapour, Dust and Mining.
  • ‘X’ Series Sensors Position Sensors for use in potentially explosive gas/vapour atmospheres.
  • ‘E’ Series Sensors Position Sensors for use in potentially explosive gas/vapour and dust atmospheres.
  • ‘M’ Series Sensors Position Sensors for use in potentially explosive gas/vapour, dust and mining environments.

ATEX logoiso 9001:2000 logoIECEx

Positek sensors are now available in the EX07 versions which are ATEX and IECEx

Qualified to Intrinsic Safety Specification

  • II 1 GD
    I M1
    Ex ia IIC T4 Ga
    Ex ia IIIC T135°C Da
    Ex ia I Ma
    Ta = -40°C to 80°C
  • Certificate number Sira 13ATEX2371X and IECEx SIR 13.0154X
  • The ambient temperature rating is extended to -40°C to 80°C.

The sensors must be used with a galvanically isolated three port amplifier
designed to supply the sensor with a nominal 5V and to transmit the buffered
output to a safe area.

The Positek X005 Galvanic Isolation Amplifier designed specifically for use with Positek Intrinsically safe sensor range is available in the following output options:

0.5 to 9.5V X005-545
9.5 to 0.5V X005-546
4 to 20mA X005-425
20 to 4mA X005-426

 

Dimensions
Body Diameter 19mm
Body Length (Axial Cable Version) Measurement length 134mm
Body Length (Axial Connector Version) Measurement length 134mm
Body Length (Radial Cable Version) Measurement length 139mm
Body Length (Radial Connector Version) Measurement length 142mm
Travel any stroke from 10 mm to 300mm (eg 205mm)
Independant Linearity <±0.25% @ 20°C
Temperature Coefficient <±0.01%/°C Gain & <±0.01%FS/°C Offset
Typical Overall Accuracy <±0.50% FSO
Resolution Infinite
Noise <0.02% FSO
Frequency Response >10KHz (-3dB);
Output Signal and Output Load
Output Signal Output Load
0.5 to 4.5 V dc ratiometric 5K Ohms min
0.5 to 9.5 V dc ratiometric 5K Ohms min
Supply current
10 mA Typical 20 mA max.
Temperature Limits
Operating -40 to 125°C
Storage -40 to 125°C
EMC Performance
Susceptibility EN 61000-6-2
Radiated EN 61000-6-3
Vibration IEC 68-2-6: 10g
Shock IEC 68-2-29: 40 g
MTBF 350,000 hrs 40°C Gf
Sealing IP67
Electrical Connections Screened 3 core cable or integral connector

Dimensions
Body Diameter 19mm
Body Length (Axial Cable Version) Measurement length 134mm
Body Length (Axial Connector Version) Measurement length 134mm
Body Length (Radial Cable Version) Measurement length 139mm
Body Length (Radial Connector Version) Measurement length 142mm
Travel any stroke from 10 mm to 300mm (eg 205mm)
Independant Linearity <±0.25% @ 20°C
Temperature Coefficient <±0.01%/°C Gain & <±0.01%FS/°C Offset
Typical Overall Accuracy <±0.50% FSO
Resolution Infinite
Noise <0.02% FSO
Frequency Response >10KHz (-3dB);
Temperature Limits
Operating -40 to 125°C
Storage -40 to 125°C
EMC Performance
Susceptibility EN 61000-6-2
Radiated EN 61000-6-3
Vibration IEC 68-2-6: 10g
Shock IEC 68-2-29: 40 g
MTBF 350,000 hrs 40°C Gf
Sealing IP67
Electrical Connections Screened 3 core cable or integral connector