P900 Series Pressure Transducer

P900 Series Pressure Transducer Description: Standard versions of this transducer use a 17-4 PH stainless steel diaphragm to sense pressure (Inconel versions are available for operation in highly corrosive environments). The deflection of the diaphragm is transferred to a double cantilever beam by a force transfer rod. Strain in the beam, […]

P900 Series Pressure Transducer

Description: Standard versions of this transducer use a 17-4 PH stainless steel diaphragm to sense pressure (Inconel versions are available for operation in highly corrosive environments). The deflection of the diaphragm is transferred to a double cantilever beam by a force transfer rod. Strain in the beam, and therefore, input pressure is measured by four foil strain gauges. An all-welded construction provides high reliability and stability.

Features:
• High Overload
• 4-20mA Output
• Intrinsic Safety

Series P900 P910 P940 P950 P960 P970 P980 P990
Model Number P901/904 P911/4 P941/4 P951/4 P961/4 P971/4 P981/4 P991/4
Input Voltage 10VDC 10VDC 10VDC 11-18VDC 18-32VDC 15-36VDC 10-36VDC ±15VDC
(12 V max) (12 V max)
Current 13 30 20 20 20 20 20
Consumption(mA)
Full Range Output (±1%) 20mV 20mV 5VDC 2.5VDC 5VDC 10VDC 4-20mA 5VDC
Impedance (ohm) 1000 ±5% 350 <10 <10 <10 <10 Load Resist. <10
1300 max. at
36VDC
Current (mA max) 5 5 5 5 5
Frequency Response Approx. 2.5 kHz Approx. 2.5 1 kHz 1 kHz 1 kHz 1 kHz 100 Hz 1 kHz
to 40 kHz for .7 kHz to 40 kHz
bar for .7 bar
Combined Thermal –
Zero & Sensitivity Shift
% F.R.O./°F ±0.008 ±0.008 ±0.008 ±0.008 ±0.008 ±0.008 ±0.008
% F.R.O./°C ±0.015 ±0.007 ±0.015 ±0.015 ±0.015 ±0.015 ±0.015 ±0.015
Residual Unbalance
% F.R.O. ±1 ±1 ±1 ±1 ±1 ±1 ±1 ±1
Weight oz (gm)
Connector Version 4.4 (125) 4.4 (125) 5.1 (145) 5.1 (145) 5.1 (145) 5.1 (145) 5.1 (145) 5.1 (145)
Cable Version 5.6 (160) 5.6 (160) 6.3 (180) 6.3 (180) 6.3 (180) 6.3 (180) 6.3 (180) 6.3 (180)

No Information Available.

No Information Available.