Series 6000 Integrated Conditioning, Acquisition & Control System

Series 6000 Integrated Conditioning, Acquisition & Control System Enclosure Details Four enclosures are available as part of the Series 6000 System: Large, Small and two DC powered portables. Common Enclosure Features Any number or combination of racks Over 6 MS/s, simultaneous sampling per system Multiple, distributed system support On-board storage […]

Series 6000 Integrated Conditioning, Acquisition & Control System

Enclosure Details

Four enclosures are available as part of the Series 6000 System: Large, Small and two DC powered portables.

Common Enclosure Features

  • Any number or combination of racks
  • Over 6 MS/s, simultaneous sampling per system
  • Multiple, distributed system support
  • On-board storage for data redundancy
  • Distributed Sample Clock, Alarm & Calibration Bus
  • IRIG A, B or G
  • Supports any I/O module in any slot

 

The native interface for the enclosure is USB 2.0 and can be configured for Ethernet. There are many ways to configure a system. Multiple racks can be combined to provide a single larger system or used individually to create smaller, lower channel count installations. The systems can be run locally (near a test cell) or remotely from a control room. This allows the test operators to setup, configure and calibrate the system locally near the test article and remotely while a test is in progress.

An Operator’s Workstation is the primary control and data recording point for the Series 6000 System. Typically installed in the control room, the Operator’s Workstation runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export. Multiple, distributed systems are supported and controlled through a single Operator’s Workstation. A system can even be configured and used over wireless technology, allowing even greater control over the system. For example, a technician can change gain and filter settings on a touch screen tablet style PC while performing system checkouts and test readiness.

Data redundancy is optionally available and mounts on the controller board in each Series 6000 enclosure, creating a redundant recording point for the system. In the unlikely event the Operator’s Workstation or application software fails, data will continue to record in each enclosure and can be recovered from the system post-test.

Enclosures

Model 6000U, Enclosure 16-Slot, USB Data & Control Interface

Features

  • Enclosure for 16 I/O modules
  • USB 2.0 Interface provides 5+ MS/s aggregate data rate
  • Calibration voltage distribution
  • Alarm busses for control external equipment
  • Optional remote operation using gigabit Ethernet
  • Optional on-board data storage
  • Built-in fans and cable tray

Description

The 6000U enclosure has 16 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. For larger systems, up to 32 enclosures may be combined using USB 2.0 hubs or a computer with multiple USB 2.0 ports. The enclosures are 8U 19-inch rack mount. The enclosures have integral fans providing air circulation and an internal cable tray that routes the input and output cables from the front of the installed modules to exit the rear of the enclosure.

A sample clock bus is provided for multi rack installations. Programming and data transfer is USB 2.0, which provides high data transfer rates with low, predictable latency. It interfaces to the USB 2.0 port provided on most PC computers including laptops. Maximum length of the interface cable is 3 meters but it may be extended further using Ethernet with the Control & Data Processor (CDP) option.

Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6000U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.

The Control & Data Processor (CDP) interfaces multiple 6000U enclosures to gigabit Ethernet providing remote and/or distributed operation. The CDP is typically installed with the Series 6000 DAS and provides an Ethernet interface to the Operators Workstation. The CDP includes a high-speed processor and software that performs low-level operations freeing resources on the Operators Workstation computer for data display, storage, distribution and reduction.

The Operators Workstation (PCCOWU) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU is typically installed in the control room and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export. In installations where the DAS is not remote from the Operators Workstation, the PCCOWU will connect directly to Series 6000 Enclosures and does not require the CDP.

Model 6010U, Enclosure 4-Slot, USB Data & Control Interface

Features

  • Enclosure for 4 I/O modules
  • USB 2.0 Interface provides 5+ MS/s aggregate data rate
  • Calibration voltage distribution
  • Alarm busses for control of external equipment
  • Optional remote operation using gigabit Ethernet
  • Optional on-board data storage
  • Built-in fans and cable tray

Description

The 6010U enclosure has 4 slots for Series 6000 input and output modules with a Universal Serial Bus (USB2.0) computer interface for programming, control and data output. For larger systems, up to 32 enclosures may be combined using USB 2.0 hubs or a computer with multiple USB 2.0 ports. The enclosures are 3U 19-inch, rack mount or desktop. The enclosures have integral fans providing air circulation and an internal cable tray that routes the input and output cables from the front of the installed modules to exit the rear of the enclosure.

A sample clock bus is provided for multi rack installations. Programming and data transfer is USB 2.0, which provides high data transfer rates with low, predictable latency. It interfaces to the USB 2.0 port provided on most PC computers including laptops. Maximum length of the interface cable is 3 meters but it may be extended further using Ethernet with the Control & Data Processor (CDP) option.

Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6010U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.

The Control & Data Processor (CDP) interfaces multiple 6000U enclosures to gigabit Ethernet providing remote and/or distributed operation. The CDP is typically installed with the Series 6000 DAS and provides an Ethernet interface to the Operators Workstation. The CDP includes a high-speed processor and software that performs low-level operations freeing resources on the Operators Workstation computer for data display, storage, distribution and reduction.

The Operators Workstation (PCCOWU) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU is typically installed in the control room and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export. In installations where the DAS is not remote from the Operators Workstation, the PCCOWU will connect directly to Series 6000 Enclosures and does not require the CDP.

Model 6005U, Enclosure 10-Slot, 12 VDC, USB Data & Control Interface

Features

  • DC Enclosure for 10 I/O Modules
  • USB 2.0 Interface provides 5+ MS/s aggregate data rate
  • Calibration voltage input
  • Alarm busses for control external equipment
  • Optional remote operation using gigabit Ethernet
  • Optional on-board data storage
  • Built-in fans and front mounted connections

Description

The 6005U enclosure has 10 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. Multiple enclosures can be combined for larger and/or distributed installations. 6005U is DC operated for mobile applications.

All connections are made on the front allowing the 6005U to be located in the tightest of spaces. It has integral fans that supply cooling air to the modules and power supply. Power is 10 to 20 VDC with 21 to 32 VDC also available. An included power adapter is provided for operation from 120/240 VAC.

A sample clock bus is provided for multi rack installations. Programming and data transfer is USB 2.0, which provides high data transfer rates with low, predictable latency. It interfaces to the USB 2.0 port provided on most PC computers including laptops. Maximum length of the interface cable is 3 meters but it may be extended further using Ethernet with the Control & Data Processor (CDP) option.

Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6005U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.

The Operators Workstation (PCCOWU-LT) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU-LT is typically a laptop, connected to the 6005U’s USB port and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export.

Model 6008U, Enclosure 4-Slot 12V DC USB Control & Data Interface

Features

  • DC Enclosure for 4 I/O Modules
  • USB 2.0 Interface provides 5+ MS/s aggregate data rate
  • Calibration voltage input
  • Alarm busses for control external equipment
  • Optional remote operation using gigabit Ethernet
  • Optional on-board data storage
  • Built-in fans and front mounted connections

Description

The 6008U enclosure has 4 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. Multiple enclosures can be combined for larger and/or distributed installations. 6008U is DC operated for mobile applications.

All connections are made on the front allowing the 6008U to be located in the tightest of spaces. It has integral fans that supply cooling air to the modules and power supply. Power is 10 to 20 VDC with 21 to 32 VDC also available. An included power adapter is provided for operation from 120/240 VAC.

A sample clock bus is provided for multi rack installations. Programming and data transfer is USB 2.0, which provides high data transfer rates with low, predictable latency. It interfaces to the USB 2.0 port provided on most PC computers including laptops. Maximum length of the interface cable is 3 meters but it may be extended further using Ethernet with the Control & Data Processor (CDP) option.

Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6008U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.

The Operators Workstation (PCCOWU-LT) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU-LT is typically a laptop, connected to the 6008U’s USB port and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export.

I/O Modules

Analog I/O Modules
Model 6013

Model 6013 8-Channel Instrumentation Amplifier-Filter-Digitizer

Features

  • Voltage, thermocouple & DC-LVDT inputs
  • Optional thermocouple reference junction box
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6013 input module has eight channels, each with programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. A ninth reference temperature channel conditions the output of the temperature sensor in the …

Model 6014

Model 6014 8-Channel Accelerometer Amplifier-Filter-Digitizer

Features

  • AC or DC coupled inputs, IEPE transducers
  • 2 to 20 mA current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four pole, low pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6014 input module has eight channels, each with AC or DC coupled programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. Each channel has a 2-20 mA current source for powering low impedance, voltage mode charge …

Model 6017

Model 6017 32-Channel Voltage/Thermocouple Amplifier-Digitizer

Features

  • Voltage & thermocouple inputs
  • Optional thermocouple reference junction box
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Low-pass filter
  • Up to 2 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6017 has thirty-two input channels organized in four eight-channel groups. The eight inputs in each group are multiplexed to a programmable gain differential amplifier and digitized with 16-bit resolution then output to the Series 6000 data bus. Each channel is capable of digitizing at up to 2,000 samples per second. The differential inputs …

Model 6018

Model 6018 8-Channel RTD/Potentiometer Amplifier-Filter-Digitizer

Features

  • RTDs, potentiometers & other current excited transducers
  • Programmable current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • Automatic zero & gain calibration
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6018 input module has eight channels, each with programmable constant current excitation, programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus.

The 6018 is used with RTDs, potentiometers …

Model 6028

Model 6028 8-Channel Voltage Digitizer with Filter

Features

  • Differential input, ±10 Volts, ±50 Volts with optional attenuator
  • Buffered ±10 Volts analog outputs for redundancy
  • Four-pole filter, 100 Hz to 20 kHz
  • Up to 100 kS/s per channel with 16-bit digitizer
  • Two alarms with programmable upper and lower limits

Description

The 6028 input module has eight channels each with a differential input, unity gain instrumentation amplifier, low pass filter and 16-bit analog to digital converter. Each channel is capable of digitizing high-frequency signals at up to 100,000 samples per second. In addition each channel has a continuous, wideband analog output.

The 6028 is used to digitize …

Model 6029

Model 6029 8-Channel AC/DC-Coupled/IEPE Amplifier-Filter-Digitizer

Features

  • AC or DC coupled inputs
  • 2 to 20 mA current excitation
  • Gains 1 to 5,000 with 0.05% accuracy
  • 4, 6 or 8-pole, low-pass filter
  • 100 kHz signal bandwidth
  • Up to 200 kS/s per channel with 16-bit resolution
  • Buffered ±10 Volt analog output

Description

The 6029 input module has eight channels each providing excitation for IEPE transducers, programmable AC or DC-coupled differential instrumentation amplifier, low-pass filter and analog to digital converter. Sample rate is programmable up to 200 kS/s with 16-bit resolution. Each channel has a buffered analog output that can be selected for wideband or filtered …

Model 6030

Model 6030 2-Channel Strain/Bridge/IEPE Amplifier-Filter-Digitizer

Features

  • Dual inputs, strain/bridge or IEPE transducers
  • Programmable bridge configuration
  • Voltage & current excitation with remote sensing per channel
  • Automatic zero & balance
  • Voltage substitution and two or four step shunt calibration
  • Gains 1 to 5,000 up to 100 kHz bandwidth with 0.05% accuracy
  • Programmable low-pass filters
  • Up to 200kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

Model 6030 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier, filter and digitizer with dual inputs. The bridge input has voltage and current excitation, …

Model 6031

Model 6031 2-Channel Transducer Amplifier-Filter-Digitizer

Features

  • Plug-in channel configuration & calibration card
  • Voltage & current excitation including remote sense
  • Gains 1 to 5,000 with 0.05% resolution
  • 50 kHz or 100 kHz bandwidth
  • Automatic zero & balance
  • Programmable low pass filters
  • Voltage substitution gain calibration
  • Digitized & analog outputs
  • Up to 250kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

Model 6031 may not be regularly available. Please see Model 6030, 6060 or 6068 for similar applications.

The 6031 is a two-channel, fully programmable signal conditioning amplifier, filter and …

Model 6032

Model 6032 4-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer

Features

  • Quarter, half & full bridge conditioning
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Fixed or programmable filter
  • Up to 20 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6032 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, programmable gain instrumentation …

Model 6033

Model 6033 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer

Features

  • Quarter, half & full bridge conditioning
  • Voltage excitation up to 12 Volts
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

Model 6033 may not be regularly available. Please see Model 6035, 6038 or 6039 for similar applications.

The 6033 input module has eight channels of transducer signal conditioning and digitizer. Each channel has regulated voltage excitation, programmable gain instrumentation amplifier, four-pole …

Model 6035

Model 6035 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer

Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Voltage excitation programmable / regulated for each channel
  • Shunt & voltage calibration
  • Automatic balance & zero
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole, low-pass filter
  • Up to 10 KS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6035 input module has eight channels of programmable transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier, four-pole low pass …

Model 6036

Model 6036 4-Channel Charge/IEPE Amplifier-Filter-Digitizer

Features

  • Dual inputs, charge & IEPE
  • 0.04 to 10,000 mV/pC charge gain
  • 2-20mA current source for IEPE transducers
  • 1 to 5,000 voltage gain with ±0.05% accuracy
  • 100 kHz bandwidth
  • Charge & voltage insertion calibration
  • Continuously programmable, 4-pole low-pass filter
  • Up to 200kS/s per channel with 16-bit resolution
  • Buffered 10 Volt analog outputs
  • Two alarms with programmable upper & lower limits

Description

Model 6036 is a four-channel, programmable charge amplifier, filter and digitizer with a second input for piezoelectric sensors with integrated electronics (IEPE).

The …

Model 6037

Model 6037 8-Channel Strain/Bridge Transducer Amplifier-Filter-Digitizer

Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Automatic gain ranging
  • Strain gage simulation resistor
  • Excitation up to 12 Volts, regulated per channel
  • Automatic balance & zero
  • Voltage & bipolar shunt calibration
  • Four frequency programmable low-pass filter
  • Up to 10kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6037 has eight channels of strain gage or transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, programmable bridge completion and automatic balance, programmable …

Model 6038

Model 6038 8-Channel Strain/Bridge Transducer Amplifier – Filter-Digitizer

Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Four-pole, low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6038 input module has eight channels of programmable transducer signal conditioning amplifiers, filters and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier and four-pole low pass filter. …

Model 6039

Model 6039 8-Channel Strain/Bridge Transducer Amplifier – Filter-Digitizer

Features

  • Programmable input configuration, 1/4, 1/2 & full bridge
  • Programmable voltage excitation with remote sensing
  • Additional 12 or 15 Volt transducer power
  • Two-step shunt & voltage substitution calibration
  • Gains 1 to 5,000 with 0.05% accuracy
  • Programmable 4, 6 or 8 pole low-pass filter
  • Up to 10 kS/s per channel with 16-bit resolution
  • Two alarms with programmable upper & lower limits

Description

The 6039 input module has eight channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage and …

Model 6052

Model 6052 4-Channel Strain/Bridge Transducer Amplifier – Filter-Digitizer

Features

  • Programmable input configuration ¼, ½ & full bridge
  • Programmable excitation with remote sensing
  • Shunt & voltage calibration
  • Automatic zero & balance
  • Gains 1 to 5,000 with 0.05% accuracy
  • Up to 20kS/s per channel with 16-bit resolution
  • Buffered 10 Volt analog output
  • Two alarms with programmable upper & lower limits

Description

The 6052 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, …

Model 6060

Model 6060 2-Channel Transducer Amplifier-Filter-Digitizer, 300CMV

Features

  • Isolated excitation & input with 300 Volts common mode
  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6060 is a two-channel signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The …

Model 6060

Model 6060GV 2-Channel Transducer Amplifier-Filter-Digitizer, Galvanic 300CMV

Features

  • Galvanically isolated excitation & input with 300 Volts common mode
  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6060GV is a two-channel Galvanically isolated signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both …

Model 6060

Model 6062 2-Channel Transducer Amplifier-Filter-Digitizer, 10CMV

Features

  • Plug-in channel configuration & calibration card
  • Voltage & current excitation with remote sensing
  • Automatic zero & balance
  • Voltage substitution, DAC or 2/4 step shunt calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Four six-pole low-pass filters, optional programmable filter
  • Up to 200 kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6062 is a two-channel signal conditioning amplifier digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The bridge input is ten-wire shielded with programmable constant voltage or …

Model 6060

Model 6065 2-Channel Instrumentation Amplifier-Filter-Digitizer, 300CMV

Features

  • Isolated input with 300 Volts common mode
  • Automatic zero
  • Voltage Substitution Calibration
  • Gains 1 to 5,000 with 50 kHz or 100 kHz bandwidth
  • Programmable low-pass filters
  • Up to 200kS/s per channel with 16-bit resolution
  • Dual buffered 10 Volt analog outputs

Description

The 6065 is a two-channel instrumentation amplifier-digitizer module. Each channel has isolated input, 100 kHz bandwidth and two outputs that can be filtered or wideband.

The input is two-wire shielded and is isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that …

Model 6068

Model 6068 2-Channel Transducer Amplifier-Filter-Digitizer, 300CMV

Features

  • Plug-in module configures channel for multiple transducer types & calibration modes
  • Voltage & current excitation with remote sensing
  • Isolated excitation & input with 300 Volts common mode
  • Voltage & shunt calibration
  • Gains 1 to 5,000 with 100 kHz bandwidth
  • Up to 200 kS/s per channel with 16-bit resolution
  • Continuously programmable 6-pole low pass filter
  • Dual buffered 10 Volt analog outputs

Description

The 6068 is a two-channel signal conditioning amplifier-digitizer module featuring 100 kHz bandwidth and both digitized and analog outputs. The base board contains both constant voltage with remote …

Digital I/O Module
Model 6040

Model 6040 16-Bit Digital Input/Output Module

Features

  • 16 Digital inputs and outputs
  • Compatible with TTL and CMOS (6040-1)
  • Optic isolated inputs (6040-2)
  • Form C relay outputs (6040-2)
  • Automatic alarm responses
  • Programmable glitch capture
  • Input/Output status display

Description

The 6040 digital I/O module provides 16 digital inputs for event recording and 16 digital outputs for control. The 6040-1 version has TTL and CMOS logic levels while the 6040-2 version has optic isolated inputs and isolated relay outputs. The 6040 may be programmed to automatically respond to the alarms generated by system input modules with preprogrammed digital outputs for the control of external …

Model 6041

Model 6041 16-Bit Test Sequencer

Features

  • 16 Digital sequencer outputs
  • Up to 16 time programmable states for each output
  • ±0.01% Time accuracy
  • TTL/CMOS or relay logic
  • 1 Millisecond resolution.

Description

The 6041 is a test sequencer that controls up to 16 digital outputs for activating facility and test equipment. The outputs may be programmed to change state at specific times before, during and after the recording of test data. The 6041-1 version has TTL/CMOS outputs while the 6041-2 version has form C relay outputs.

The 6041 is used to control external equipment in a programmed time sequence. Each of the 16 outputs may be programmed to change state sixteen times at …

Model 6042

Model 6042 DSP Control Processor with Analog-Digital I/O

Features

  • Floating point digital signal processor with 16 or 32 MB program/data memory
  • ±10 Volt analog outputs (DAC) with smoothing filter
  • 64 Recordable outputs with alarms
  • Analog & digital output expansion on daughter board
  • Preprogrammed algorithms
  • JTAG and IEEE 1145.1 Buffered Serial Ports

Description

The 6042 Control Processor with analog and digital outputs adds real time processing and control operations to the Series 6000 data acquisition systems. It is appropriate for PID control loops including fast decisions such as test shutdown due to limit violations, frequency analysis, waveform generation, derived parameter calculation …

Model 6044

Model 6044 32-Bit Discrete Input/Output with Alarms

Features

  • 32 Discrete digital inputs/outputs
  • TTL/CMOS or isolated (28V) inputs
  • TTL or open collector outputs
  • Program Mode for direct programming of discrete outputs
  • Alarm Mode generates discrete outputs based on limits set for measurement channels
  • Programmable persistence prevents false alarms

Description

The 6044 is a discrete I/O module that can be user configured to have 32 digital outputs, 32 digital inputs or 16 digital inputs and 16 digital outputs. The digital outputs may be directly programmed or programmed to change state when the output of one or more measurement channels in the same enclosure violate programmed alarm …

Model 6047

Model 6047 IRIG Time Code Reader

Features

  • IRIG A, B and G
  • 1 Microsecond resolution
  • 100 mV to 10 Volt peak-to-peak input
  • Days, hours, minutes, seconds, milliseconds and microseconds
  • Simultaneous BCD and binary outputs
  • Time kept by disciplined clock if IRIG signal is lost

Description

The 6047 IRIG Time Code Reader provides precision time references for measurement data acquired by the 6000 data acquisition system. Time is acquired from time code signals, IRIG A, B or G, applied to the BNC input. Time data is captured by the 6000’s sample clock and can be selectively output in the multiplexed data stream with measurement data at any available sample rate. It enables data …

Model 6048

Model 6048 4-Channel 32-Bit Frequency/Period/Counter

Features

  • Four independent 32-bit channels
  • Digital or zero crossing triggers
  • Optic isolated inputs
  • Noise reduction input filters
  • Programmable time base
  • 12 Volt isolated power for inputs
  • Companion Calibration Relay Matrix

Description

The 6048 is a four-channel input module for use with tachometers, flowmeters and other transducers that have frequency outputs. It can also measure the period between events and count or totalize events. Digital measurement of frequency provides the highest accuracy. Much better, for example, than-voltage-to frequency converters.

The 6048 has optic isolated trigger, pause and reset inputs and may be …

Model 6048

Model 6049 Quad 32-Bit Quadrature Decoder

Feature

  • Four independent 32-bit channels
  • Optic isolated inputs
  • Noise reduction input filters
  • 12 Volt isolated power for inputs

Description

The 6049 is a four-channel input module for use with quadrature encoders. Each channel has optical isolation for the “A”, “B”, and “Z” inputs. The “A” and “B” quadrature inputs feed a 32 bit up/down accumulator, that may be set or cleared under program control. The up/down polarity for each 32 bit accumulator is programmable. A short debounce filter for the “A”, “B”, and “Z” inputs can be programmed for 0 to 230 nsec.

No Information Available.