Call Us Now! (03) 9874 5777Contact Us
Series 6000 Integrated Conditioning, Acquisition & Control System Enclosure Details Four enclosures are available as part of the Series 6000 System: Large, Small and two DC powered portables. Common Enclosure Features Any number or combination of racks Over 6 MS/s, simultaneous sampling per system Multiple, distributed system support On-board storage […]
Four enclosures are available as part of the Series 6000 System: Large, Small and two DC powered portables.
The native interface for the enclosure is USB 2.0 and can be configured for Ethernet. There are many ways to configure a system. Multiple racks can be combined to provide a single larger system or used individually to create smaller, lower channel count installations. The systems can be run locally (near a test cell) or remotely from a control room. This allows the test operators to setup, configure and calibrate the system locally near the test article and remotely while a test is in progress.
An Operator’s Workstation is the primary control and data recording point for the Series 6000 System. Typically installed in the control room, the Operator’s Workstation runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export. Multiple, distributed systems are supported and controlled through a single Operator’s Workstation. A system can even be configured and used over wireless technology, allowing even greater control over the system. For example, a technician can change gain and filter settings on a touch screen tablet style PC while performing system checkouts and test readiness.
Data redundancy is optionally available and mounts on the controller board in each Series 6000 enclosure, creating a redundant recording point for the system. In the unlikely event the Operator’s Workstation or application software fails, data will continue to record in each enclosure and can be recovered from the system post-test.
The 6000U enclosure has 16 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. For larger systems, up to 32 enclosures may be combined using USB 2.0 hubs or a computer with multiple USB 2.0 ports. The enclosures are 8U 19-inch rack mount. The enclosures have integral fans providing air circulation and an internal cable tray that routes the input and output cables from the front of the installed modules to exit the rear of the enclosure.
A sample clock bus is provided for multi rack installations. Programming and data transfer is USB 2.0, which provides high data transfer rates with low, predictable latency. It interfaces to the USB 2.0 port provided on most PC computers including laptops. Maximum length of the interface cable is 3 meters but it may be extended further using Ethernet with the Control & Data Processor (CDP) option.
Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6000U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.
The Control & Data Processor (CDP) interfaces multiple 6000U enclosures to gigabit Ethernet providing remote and/or distributed operation. The CDP is typically installed with the Series 6000 DAS and provides an Ethernet interface to the Operators Workstation. The CDP includes a high-speed processor and software that performs low-level operations freeing resources on the Operators Workstation computer for data display, storage, distribution and reduction.
The Operators Workstation (PCCOWU) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU is typically installed in the control room and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export. In installations where the DAS is not remote from the Operators Workstation, the PCCOWU will connect directly to Series 6000 Enclosures and does not require the CDP.
The 6010U enclosure has 4 slots for Series 6000 input and output modules with a Universal Serial Bus (USB2.0) computer interface for programming, control and data output. For larger systems, up to 32 enclosures may be combined using USB 2.0 hubs or a computer with multiple USB 2.0 ports. The enclosures are 3U 19-inch, rack mount or desktop. The enclosures have integral fans providing air circulation and an internal cable tray that routes the input and output cables from the front of the installed modules to exit the rear of the enclosure.
Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6010U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.
The 6005U enclosure has 10 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. Multiple enclosures can be combined for larger and/or distributed installations. 6005U is DC operated for mobile applications.
All connections are made on the front allowing the 6005U to be located in the tightest of spaces. It has integral fans that supply cooling air to the modules and power supply. Power is 10 to 20 VDC with 21 to 32 VDC also available. An included power adapter is provided for operation from 120/240 VAC.
Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6005U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.
The Operators Workstation (PCCOWU-LT) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU-LT is typically a laptop, connected to the 6005U’s USB port and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export.
The 6008U enclosure has 4 slots for Series 6000 input and output modules with a Universal Serial Bus (USB 2.0) computer interface for programming, control and data output. Multiple enclosures can be combined for larger and/or distributed installations. 6008U is DC operated for mobile applications.
All connections are made on the front allowing the 6008U to be located in the tightest of spaces. It has integral fans that supply cooling air to the modules and power supply. Power is 10 to 20 VDC with 21 to 32 VDC also available. An included power adapter is provided for operation from 120/240 VAC.
Data Redundancy is optionally available. A 2.5″ HD (Module 6095) mounts on the USB controller board in each 6008U enclosure and provides a redundant recording point for the DAS. In the unlikely event the Operators Workstation or DAS Software fails, data will continue to record in each enclosure. Data can be recovered from the system post-test.
The Operators Workstation (PCCOWU-LT) is the primary control and data recording point for the Series 6000 DAS. The PCCOWU-LT is typically a laptop, connected to the 6008U’s USB port and runs PI660 Data Acquisition Software for system setup, calibration, display, recording, distribution and export.
The 6013 input module has eight channels, each with programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. A ninth reference temperature channel conditions the output of the temperature sensor in the …
The 6014 input module has eight channels, each with AC or DC coupled programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus. Each channel has a 2-20 mA current source for powering low impedance, voltage mode charge …
The 6017 has thirty-two input channels organized in four eight-channel groups. The eight inputs in each group are multiplexed to a programmable gain differential amplifier and digitized with 16-bit resolution then output to the Series 6000 data bus. Each channel is capable of digitizing at up to 2,000 samples per second. The differential inputs …
The 6018 input module has eight channels, each with programmable constant current excitation, programmable gain instrumentation amplifier, low pass filter and sample and hold. The high level outputs are multiplexed and digitized to 16 bits then output to the 6000 data bus.
The 6018 is used with RTDs, potentiometers …
The 6028 input module has eight channels each with a differential input, unity gain instrumentation amplifier, low pass filter and 16-bit analog to digital converter. Each channel is capable of digitizing high-frequency signals at up to 100,000 samples per second. In addition each channel has a continuous, wideband analog output.
The 6028 is used to digitize …
The 6029 input module has eight channels each providing excitation for IEPE transducers, programmable AC or DC-coupled differential instrumentation amplifier, low-pass filter and analog to digital converter. Sample rate is programmable up to 200 kS/s with 16-bit resolution. Each channel has a buffered analog output that can be selected for wideband or filtered …
Model 6030 is a two-channel, fully automated, high bandwidth, signal conditioning amplifier, filter and digitizer with dual inputs. The bridge input has voltage and current excitation, …
Model 6031 may not be regularly available. Please see Model 6030, 6060 or 6068 for similar applications.
The 6031 is a two-channel, fully programmable signal conditioning amplifier, filter and …
The 6032 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, programmable gain instrumentation …
Model 6033 may not be regularly available. Please see Model 6035, 6038 or 6039 for similar applications.
The 6033 input module has eight channels of transducer signal conditioning and digitizer. Each channel has regulated voltage excitation, programmable gain instrumentation amplifier, four-pole …
The 6035 input module has eight channels of programmable transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier, four-pole low pass …
Model 6036 is a four-channel, programmable charge amplifier, filter and digitizer with a second input for piezoelectric sensors with integrated electronics (IEPE).
The …
The 6037 has eight channels of strain gage or transducer signal conditioning amplifiers and digitizer. Each channel has programmable voltage excitation, programmable bridge completion and automatic balance, programmable …
The 6038 input module has eight channels of programmable transducer signal conditioning amplifiers, filters and digitizer. Each channel has programmable voltage excitation, bridge completion and balance, programmable gain instrumentation amplifier and four-pole low pass filter. …
The 6039 input module has eight channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage and …
The 6052 input module has four channels of high performance signal-conditioning amplifier-digitizers for strain gages and bridge transducers. Each channel has programmable excitation with remote sensing, voltage calibration, local or remote shunt calibration, …
The 6060 is a two-channel signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The …
The 6060GV is a two-channel Galvanically isolated signal conditioning amplifier-digitizer module with 50 kHz or 100 kHz bandwidth and both …
The 6062 is a two-channel signal conditioning amplifier digitizer module with 50 kHz or 100 kHz bandwidth and both digitized and analog outputs. The bridge input is ten-wire shielded with programmable constant voltage or …
The 6065 is a two-channel instrumentation amplifier-digitizer module. Each channel has isolated input, 100 kHz bandwidth and two outputs that can be filtered or wideband.
The input is two-wire shielded and is isolated from the outputs, power and control interface. This gives the user complete freedom to ground the input without creating ground loops that …
The 6068 is a two-channel signal conditioning amplifier-digitizer module featuring 100 kHz bandwidth and both digitized and analog outputs. The base board contains both constant voltage with remote …
The 6040 digital I/O module provides 16 digital inputs for event recording and 16 digital outputs for control. The 6040-1 version has TTL and CMOS logic levels while the 6040-2 version has optic isolated inputs and isolated relay outputs. The 6040 may be programmed to automatically respond to the alarms generated by system input modules with preprogrammed digital outputs for the control of external …
The 6041 is a test sequencer that controls up to 16 digital outputs for activating facility and test equipment. The outputs may be programmed to change state at specific times before, during and after the recording of test data. The 6041-1 version has TTL/CMOS outputs while the 6041-2 version has form C relay outputs.
The 6041 is used to control external equipment in a programmed time sequence. Each of the 16 outputs may be programmed to change state sixteen times at …
The 6042 Control Processor with analog and digital outputs adds real time processing and control operations to the Series 6000 data acquisition systems. It is appropriate for PID control loops including fast decisions such as test shutdown due to limit violations, frequency analysis, waveform generation, derived parameter calculation …
The 6044 is a discrete I/O module that can be user configured to have 32 digital outputs, 32 digital inputs or 16 digital inputs and 16 digital outputs. The digital outputs may be directly programmed or programmed to change state when the output of one or more measurement channels in the same enclosure violate programmed alarm …
The 6047 IRIG Time Code Reader provides precision time references for measurement data acquired by the 6000 data acquisition system. Time is acquired from time code signals, IRIG A, B or G, applied to the BNC input. Time data is captured by the 6000’s sample clock and can be selectively output in the multiplexed data stream with measurement data at any available sample rate. It enables data …
The 6048 is a four-channel input module for use with tachometers, flowmeters and other transducers that have frequency outputs. It can also measure the period between events and count or totalize events. Digital measurement of frequency provides the highest accuracy. Much better, for example, than-voltage-to frequency converters.
The 6048 has optic isolated trigger, pause and reset inputs and may be …
The 6049 is a four-channel input module for use with quadrature encoders. Each channel has optical isolation for the “A”, “B”, and “Z” inputs. The “A” and “B” quadrature inputs feed a 32 bit up/down accumulator, that may be set or cleared under program control. The up/down polarity for each 32 bit accumulator is programmable. A short debounce filter for the “A”, “B”, and “Z” inputs can be programmed for 0 to 230 nsec.
No Information Available.
Your Name (required)
Your Email (required)
Business Name (required)
Your Phone Number (required)
Subject
Your Message