Wireless Sensor Transmitter for K-Type Thermocouple Acquisition T24-ACMi-TCA

The T24-ACMi-TCA is a high-performance wireless temperature transmitter designed for direct connection to K-type thermocouples. Housed in a rugged IP67-rated ACMi enclosure, it forms part of the Mantracourt T24 modular telemetry range and enables reliable, real-time wireless transmission of temperature data across a broad range of applications.

This module accepts a single K-type thermocouple input and supports a wide measurement range from -200 °C to +1300 °C (-328 °F to +2372 °F), delivering fast and accurate temperature readings in both ambient and extreme environments. It is particularly well-suited to construction, industrial heating, R&D, and predictive maintenance applications where embedded or remote monitoring is required.

Using a licence-free 2.4 GHz DSSS radio band, the T24-ACMi-TA transmits secure, interference-resistant data with a wireless range of up to 800 metres (2,600 feet) line-of-sight. The integral antenna and compact IP67 enclosure make it easy to install in harsh environments, while full compatibility with all T24 receivers—including handhelds, relay modules, PLCs, PCs, and the SensorSpace cloud platform—offers complete system flexibility.

Designed for long-term use in battery-powered systems, the T24-ACMi-TA features ultra-low power operation with configurable transmission intervals ranging from once per day to 200 samples per second. The module can be remotely placed into low-power sleep mode and reactivated over the air by other T24 devices, supporting efficient remote monitoring and power management.

Setup, calibration, and diagnostics are performed wirelessly using the free T24 Toolkit software, with calibration data stored internally to simplify field deployment and system integration.

Typical Applications

  • Embedded temperature monitoring in concrete curing
  • High-temperature process equipment and industrial heating systems
  • R&D and test laboratory setups
  • Predictive maintenance for rotating or high-stress machinery

Module transmits and receives, offering:

  1. Full error detection and correction
  2. Calibration and configuration via radio telemetry
  3. Ability to be switched from sleep to operating mode via radio
  4. Thermocouple calibration stored within the module
  5. Remote battery check
  6. Data encryption for complete security (128-bit AES)

Maximum range achieved in open field site with the T24 acquisition module at a height of 3 metres (9.8 feet) above ground and T24-HS held at chest height pointing towards the acquisition module. Specification at 3V supply at 25°C.

Product Features and Benefits

  • Wireless transmitter for K-type thermocouples with direct sensor input
  • Wide temperature measurement range: -200 °C to +1300 °C (-328 °F to +2372 °F)
  • Compact IP67-rated ACMi enclosure with integral antenna
  • Wireless range up to 800 m (2,600 ft) line-of-sight
  • Optimised for fast response and accurate readings in both static and dynamic applications
  • Ultra-low power consumption with configurable transmission intervals (1/day to 200/sec)
  • Remote sleep/wake control via T24 wireless network
  • Compatible with all T24 receivers including handhelds, PLCs, analogue outputs, and cloud systems
  • Wireless configuration, calibration, and diagnostics using free T24 Toolkit software
  • Internal storage of calibration data for quick deployment
  • Full error correction and 128-bit AES encrypted transmission for secure data integrity

Specification

Measurement Specification

Temperature Range -200 to 1300°C
Accuracy -50 to +0 °C ± 2°C
Accuracy 0 to 1000 °C ± (0.5% + 1)°C
Accuracy 1000 to 1300 °C ± (0.8% + 1)°C
Internal Resolution 16,000,000/ 24 Resolution/bits
Noise Free where Sample Time < 5ms 13,000 / 13.5 Resolution/bits
Noise Free where Sample Time < 10ms 17,000 / 14 Resolution/bits
Noise Free where Sample Time < 100ms 62,000 / 16 Resolution/bits
Noise Free where Sample Time > 1000ms 0.1 %FR
Noise Free where Sample Time < 10ms 5,000 / 12.5 Resolution/Bits
Noise Free where Sample Time < 100ms 6,000 / 12.75 Resolution/Bits
Noise Free where Sample Time < 1000ms 10,000 / 13.25 Resolution/Bits
Noise Free where Sample Time > 1000ms 158,000 / 17 Resolution/bits

Environmental

Operating temperature range -20 to 55 ºC
Storage temperature range (no batteries) -40 to 85 ºC
Maximum humidity 95%RH
Environmental protection IP67

Power Supply

Standby / Low Power Mode 5-20 μA
Normal Mode on constantly 40-45 mA

Battery Life in Low Power Mode

Generating Results at 3Hz

Pair AA cells constantly on 1 month
Pair AA cells 12 sessions per day of 5 mins 2 years
Pair D cells constantly on 4.5 months
Pair D cells 12 sessions per day of 5 mins > 9 years

Radio

Radio type Licence exempt transceiver
Radio frequency 2.4 GHz
Transmit power 10 mW
Range Up to 800m
Antenna Integrated or External (option)

Downloads

T24-TCA Product Sheet

T24 Wireless Telemetry User Manual V.01-16

T24 Wireless Telemetry Toolkit Version 02.25.00

100 Channel Logging & Visualisation Software (T24LOG100)

T24 Enclosure Comparison Sheet

White Paper – A Guide to Effective T24 Wireless Telemetry Installation

Technical Guide – Carrying Out a Wireless Site Survey

White Paper – Getting The Best From Wireless Instrumentation

T24 Wireless Telemetry Step File Pack

80mm X 62mm X 34mm (Not including cable gland)