ATEQ F520 Series Leak Tester

ATEQ F520 Series Leak Tester Without any doubt the smallest high-performance leak detector on the market. Specially adapted for automatic test machines or semi-automatic test machines, the F520 has a full range of specifications at a very competitive price. Differential pressure decay leak measurement. Ranges of leak measurement (ΔP) full […]

ATEQ F520 Series Leak Tester

Without any doubt the smallest high-performance leak detector on the market. Specially adapted for automatic test machines or semi-automatic test machines, the F520 has a full range of specifications at a very competitive price.

  • Differential pressure decay leak measurement.
  • Ranges of leak measurement (ΔP) full scale: 50 Pa – 500 Pa – 5000 Pa
  • Test modes:
    • ΔP
    • ΔP/Δt
    • Flow Units
    • Blockage test
    • And others, depending on your applications
  • New, faster system to fill parts
  • Manual calibration on front panel with calibrated leak
  • 32 programs
  • 7 inputs/5 outputs
  • Time and date display, choice of languages and units, customisation of tests for your requirements.

 

F520

Technology  Differential pressure decay
Measurement range  3 ranges of leakmeasurement (DP)
Full scale :
50 Pa 500 Pa 5 000 Pa
Test modes  Test modes : DP
DP/Dt
Flow units
Blocage test
Additional ones depending
on your applications
Programs 64 programs / head
Calibration Manual calibration on frontpanel using calibrated leak
Networking RS232: PC and
configuration storage
module
RS485: ATEQ network
Dimensions W/H/D (mm) 250 x 136x 367
Weight (Kg) 8
Interface Navigation keys
LCD display 4 lines
Results indicator lights
Power supply 24 V DC 1 .6 AMain adapter
included (110 – 240 V AC)
Air requirements Clean and dry air requiredAir quality standard to be
applied (ISO 8573-1)
Temperature Operating: 0°C to 45°CStorage: 0°C to 60°C
Options Electronic regulatorDual pressure
High speed valve
Y valve: 2 test ports
2 pneumatic outputs for
control of sealing connectors
6 x 24 V programmable
outputs for external
automation
2 analog outputs:
0 – 10 V or 4 – 20mA
Automatic calibration check
Temperature compensation
Modbus (Field bus)
Dimensions W/H/D (mm) 250 x 136x 367
Temperature Operating: 0°C to 45°CStorage: 0°C to 60°C