C2D1

C2D1 Off Centre Load Cell

The off center load cell C2D1 can be used in different sectors as it maintains precision even where the loads are not well centered and static, it is characterized by high accuracy and low pressure. The customer can customize the C2D1 cell based on the type of application, for example the capacity can vary from 100 kg to 800 kg and the maximum dimensions of the plate are 450 x 650 mm. The C2D1 cell has a 4-conductor shielded cable.

Technical Specifications

Rated load RL: 100, 120, 300, 450, 600, 800 Kg
Combined error: < ±0.02 % RO
Repeatability: < ±0.018 % RO
Creep (30 minutes): ±0.012 % RO
Safe overload: 150 % RL
Ultimate overload: 200 % RL
Material: Alluminum alloy
Degree of protection: IP65
Deflection: 0.13 ÷ 0.46 mm
Compensated Temperature: -10 ÷ +40°C
Temperature range: -20 ÷ +70 °C
Temperature effect on zero balance: < ±0.0014 % RO/°C
Temperature effect on output: < ±0.001 % RO/°C
Rated output RO: 2 (+0.004, -0) mV/V
Zero balance: < ±0.1 mV/V
Insulation resistance: >2000 MOhm
Input resistance: 420 ± 40 Ohm
Output resistance: 350 ±3 Ohm
Recommended input: 5 ÷ 12 Vdc/Vac
Maximum supply voltage: 16 V