C2G1 HT

C2G1 HT High Temperature Load Cell

The C2G1 HT load cell is suitable for high temperatures and it is particularly suitable for the construction of industrial and bench scales, piece counters and packaging machines. The C2G1 HT cell also measures correctly with off-center loads while maintaining high accuracy and reliability.

Technical Specifications

Rated load RL: 6, 10, 12, 15, 20, 25, 30, 35, 50, 60, 100 Kg
Repeatability: ±0,02 % RO
Creep (20 minutes): ±0,02 % RO
Full scale non-Linearity: ±0,015 % RO
Safe overload: 150 % RL
Ultimate overload: 200 % RL
Material: Stainless steel
Degree of protection: IP64
Accuracy class: 3000 OIML – 6000 OIML
Deflection: 0.17 ÷ 0.62 mm
Compensated Temperature: -10 ÷ +120 °C
Temperature range: -10 ÷ +150 °C
Temperature effect on zero balance: ±0.004 % RO/°C
Temperature effect on output: ±0.0012 % load/°C
Rated output RO: 2 mV/V ±0.2
Zero balance: < ±0.1 mV/V
Insulation resistance: > 2000 MOhm
Input resistance: 420 ± +30/-20 Ohm
Output resistance: 350 ±5 Ohm
Recommended input: 5 ÷ 12 Vdc/ac