HR Series LVDT

HR Series LVDT Description:  The HR Series general purpose LVDTs provide the optimum performance required for a majority of applications. The large 1/16 inch [1.6mm] bore-to-core radial clearance provides for ample installation misalignments and therefore reduces the application costs. Featuring a high output voltage and a broad operating frequency range, […]

HR Series LVDT

Description: 

The HR Series general purpose LVDTs provide the optimum performance required for a majority of applications. The large 1/16 inch [1.6mm] bore-to-core radial clearance provides for ample installation misalignments and therefore reduces the application costs. Featuring a high output voltage and a broad operating frequency range, these versatile and highly reliable LVDTs deliver worry-free and precise position measurements.

Features:

  • 0.25% linearity (100% stroke)
  • Large 1/16″ core-to-bore clearance
  • Shock and vibration tolerant
  • Electromagnetic/electrostatic shielding
  • Calibration certificate supplied with each unit

 

ELECRTICAL SPECIFICATIONS

Parameter HR
050
HR
100
HR
200
HR
300
HR
500
HR
1000
HR
2000
HR
3000
HR
4000
HR
5000
HR
7500
HR
10000
Stroke range ±0.05
[±1.27]
±0.1
[±2.54]
±0.2
[±5.08]
±0.3
[±7.62]
±0.5
[±12.7]
±1
[±25.4]
±2
[±50.8]
±3
[±76.2]
±4
[±101.6]
±5
[±127]
±7.5
[±190.5]
±10
[±254]
Sensitivity V/V/inch
[mV/V/mm]
5.8
[228]
4.2
[165]
2.5
[98.4]
1.3
[51.2]
0.7
[27.6]
0.39
[15.4]
0.23
[9.1]
0.25
[9.8]
0.20
[7.9]
0.14
[5.5]
0.13
[5.1]
0.07
[2.8]
Output
at stroke ends, mV/V (*)
290 420 500 390 350 390 460 750 800 700 975 700
Phase shift -1° -5° -4° -11° -1° -3° 11° -5°
Input
impedance
(PRIMARY)
430Ω 1070Ω 1150Ω 1100Ω 460Ω 460Ω 330Ω 315Ω 275Ω 310Ω 260Ω 550Ω
Output
impedance
(SECONDARY)
4000Ω 5000Ω 4000Ω 2700Ω 375Ω 320Ω 300Ω 830Ω 400Ω 400Ω 905Ω 750Ω
Non-linearity

% of FR

@ 50% stroke 0.10 0.10 0.10 0.10 0.15 0.15 0.15 0.15 0.15 0.15 / 0.15
@100% stroke
(maximum)
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
@125% stroke 0.25 0.25 0.25 0.35 0.35 1.00 0 .50 0 .50 0 .50 1.00 / 1.00
@150% stroke 0.50 0.50 0.50 0.50 0.75 1.30 1.00 1.00 1.00 / / /
Input voltage 3 VRMS sine wave
Input frequency 400Hz to 5kHz
Test frequency 2.5kHz
Null voltage 0.5% of FRO, maximum

 

ENVIRONMENTAL SPECIFICATIONS & MATERIALS
Operating temperature -65°F to 300°F [-55°C to 150°C]
Shock survival 1,000 g (11ms half-sine)
Vibration tolerance 20 g up to 2KHz
Housing material AISI 400 Series stainless steel
Electrical connection Six lead-wires, 28 AWG stranded Copper, PTFE insulated, 1 foot [30cm] long

https://appliedmeasurement.com.au/ama/wp-content/uploads/2014/04/HR_Series.pdf

No Information Available.

Operating temperature -65°F to 300°F [-55°C to 150°C]