MAGPOWR Cygnus Tension Control

MAGPOWR Cygnus Tension Control A variety of advanced yet easy-to-use features are apparent immediately to operators using MAGPOWR’s compact, powerful Cygnus® Tension Controls. Operators can easily navigate through advanced tension control functions and codes using on-screen prompts displayed in full text, making the setup process faster. Web tension is maintained […]

MAGPOWR Cygnus Tension Control

A variety of advanced yet easy-to-use features are apparent immediately to operators using MAGPOWR’s compact, powerful Cygnus® Tension Controls. Operators can easily navigate through advanced tension control functions and codes using on-screen prompts displayed in full text, making the setup process faster. Web tension is maintained or adjusted using multifunction “smart keys,” similar to those used in ATMs, and a large backlit display for easy viewing. Converters and printers can dramatically reduce setup time and improve consistency with powerful features like automatic tuning and out of round roll compensation (previously only possible with a dancer control). Complex tension settings can be input quickly with full text prompts as opposed to more complicated input procedures of the past.

  • Web Break Detection
  • Out-of-Round Roll Compensation
  • Bus Communication Capability
  • Auto Tuning
  • Weightless Load Cell Calibration
  • Advanced Load Cell Diagnostics
  • Gain Scheduling
  • UL and CE Approved

 

Certifications CE
UL 508C Listed
Input
Supply Voltage 115/230 VAC /- 10%, 50/60 Hz, switch selectable
Tension Input 0 to 21 mVDC (1 or 2, 350 Ω full bridges), 0 to 500 mVDC

(1 or 2, 120 Ω bridge), 0 to 5 VDC, 1 mADC maximum

Diameter Input 0 to 10 VDC analog or calculated using velocity/rpm
RPM or Web Speed 0 to 10 VDC analog, or

0.01 to 50,000 pulses per second, 5 VDC or 24 VDC logic

Auxiliary Input 0 to 10 VDC
E-Stop, Run/Stop, Tension Off, Format, Splice switch closure,

5 or 24 VDC logic, active high or low

Output
Torque 0 to 10 VDC, 4 to 20 mADC (500 Ω max), -10 to 10 VDC
Inverse Diameter 0 to 10 VDC, 1 mADC maximum
Tension Reference 0 to 10 VDC, 1 mADC maximum
Load Cell Excitation 5 or 10 VDC, 5 and -5 VDC (10 VDC)
Low Tension (Web Break) Tension Status DC solid state relay, 100 mADC

with a 1.6 VDC drop, 30 VDC max, or

5 mADC with a 0.6 VDC drop 30 VDC maximum

Weight
Cygnus-DIN 1.8 kg
Cygnus-E 5 kg
Temperature
E-Operating 0 to 40˚ C
DIN Operating 0 to 50˚ C
Storage -30 to 80˚ C
Enclosure
Cygnus-DIN Front Panel IP65 (IEC529)

Enclosure IP20 (IEC529)

Cygnus-EIP65 (IEC529)
Bus Communication Gateways
COMMKIT-DN DeviceNet
COMMKIT-EN Ethernet/IP
COMMKIT-PB Profibus-DP

CERTIFICATIONS

 

No Information Available.

Temperature
E-Operating 0 to 40˚ C
DIN Operating 0 to 50˚ C
Storage -30 to 80˚ C