CX,CX77 Series Load Cell

CX,CX77 Series Load Cell High Precision Accuracy Compression Service. Hopper, Tank Weighing. Protection Class IP67 Specifications Accuracy  CXH CXM CXG Rated capacity(R.C) 1tf, 2tf, 3tf, 5tf, 10tf, 20tf 100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 30ft, 50ft, 100tf, 200tf, 300tf, 500tf Rated output(R.O) 2.0mV/V±0.1% 2.0mV/V±0.1(50tf~500tf : 1.5mV/V±0.1%) Nonlinearity […]

CX,CX77 Series Load Cell

  • High Precision Accuracy Compression Service.
  • Hopper, Tank Weighing.
  • Protection Class IP67

Specifications

Accuracy

 CXH

CXM

CXG

Rated capacity(R.C)

1tf, 2tf, 3tf, 5tf, 10tf, 20tf

100kgf, 200kgf, 500kgf, 1tf, 2tf, 3tf, 5tf, 10tf, 20tf, 30ft, 50ft, 100tf, 200tf, 300tf, 500tf

Rated output(R.O)

2.0mV/V±0.1%

2.0mV/V±0.1(50tf~500tf : 1.5mV/V±0.1%)

Nonlinearity

0.02% of R.O.

0.05% of R.O.

0.1% of R.O.
(200, 300, 500tf : 0.5% of R.O.)

Hysteresis

0.02% of R.O

0.05% of R.O

0.1% of R.O.
(200, 300, 500tf : 0.5% of R.O.)

Repeatability

0.02% of R.O

0.05% of R.O

0.1% of R.O.

Zero balance

±1% of R.O.

Temperature effect, on rated output

0.03% of LOAD/10℃

0.1% of LOAD/10℃

Temperature effect, on zero balance

0.03% of R.O./10℃

0.1% of R.O./10℃

Temperature range, compensated

-10~60℃

Temperature range, safe

-20~80℃

Terminal resistance input

350±5Ω

Terminal resistance output

350±5Ω

Insulation resistance bridge/case

5000MΩ

Excitation recommended

10V

Safe overload

150% R.C.

Cable length

Φ7mm 4core,3m

 

No Information Available.

No Information Available.